[Is uterine height able to diagnose amniotic fluid volume deviations?].
نویسندگان
چکیده
PURPOSE To evaluate the performance of a Brazilian reference curve of fundal height (FH) regarding its capacity of screening the deviations of volume of amniotic fluid using a Brazilian reference curve of amniotic fluid index (AFI) as gold standard. METHODS This was a cross-sectional study evaluating 753 pregnant women receiving prenatal care at the public health services of João Pessoa (PB), from March to October 2006, who had a routine ultrasound exam scheduled for after 26 weeks of gestational age. Cases with diagnoses of twin pregnancy, intrauterine fetal death and major fetal malformations were excluded. Besides socio-demographic information, data regarding fundal height measured in a standard way, estimated fetal weight, AFI and gestational age at the time of the ultrasound exam were also collected. The capacity of the FH curve to predict deviations of the amniotic fluid volume was assessed using the Brazilian curve of AFI according to gestational age as the gold standard. For this purpose, sensitivity, specificity, positive and negative predictive values were estimated for different cut-off points. RESULTS The measurement of FH identified 10.5% of women as having low FH possibly associated with oligohydramnios and 25.2% as having high FH possibly associated with polyhydramnios. Using a Brazilian reference curve of AFI, the FH was able to poorly predict the occurrence of oligohydramnios (sensitivity ranging from 37 to 28%) and to reasonably predict the occurrence of polyhydramnios (sensitivity ranging from 88 to 69%). CONCLUSIONS The measurement of fundal height showed a poor performance for predicting oligohydramnios and a reasonable performance for predicting polyhydramnios. Its use for this purpose is then only supported in settings where the ultrasound exam is not easily or routinely available in order to help define priorities for cases that should have this exam performed.
منابع مشابه
Amniotic Fluid Deficiency and Congenital Abnormalities both Influence Fluctuating Asymmetry in Developing Limbs of Human Deceased Fetuses
Fluctuating asymmetry (FA), as an indirect measure of developmental instability (DI), has been intensively studied for associations with stress and fitness. Patterns, however, appear heterogeneous and the underlying causes remain largely unknown. One aspect that has received relatively little attention in the literature is the consequence of direct mechanical effects on asymmetries. The crucial...
متن کاملAmniotic fluid index measurements in normal pregnancy after 28 gestational weeks.
OBJECTIVE The purpose of this study is to establish a normative scale of amniotic fluid index (AFI) or four-quadrant amniotic fluid index throughout gestation in uncomplicated singleton pregnancies, and to identify the lower and upper limits for each gestational week. METHOD A prospective longitudinal study was used. One hundred seventeen uncomplicated singleton pregnancies were examined ever...
متن کاملAssessment of amniotic fluid index in normal pregnancy at a tertiary care hospital setting.
BACKGROUND Ultrasound assessment of amniotic fluid has important implication in obstetrics care and it has become an integral and important component of pregnancy assessment. Changes in amniotic fluid volume are associated with adverse outcome. Excess volume is associated with foetal anomalies and aneuploidy and less volume is associated with Intra Uterine Growth Retardation, renal anomalies in...
متن کاملEvaluation and Prediction of the Impact of Parasite Waves and Cell Phone Use by Pregnant Mothers on the Volume of Amniotic Fluid based on Data Mining Algorithms
Introduction: Nowadays, the effects of radiation and constant use of cell phones have led to some problems. These radiations cause disorders in different systems of human body and even in a growing fetus. The aim of this study was to find the effect of using cell phone and internet by pregnant women on the amount of amniotic fluid. Method: First, a questionnaire was designed and evaluated by o...
متن کاملEvaluation and Prediction of the Impact of Parasite Waves and Cell Phone Use by Pregnant Mothers on the Volume of Amniotic Fluid based on Data Mining Algorithms
Introduction: Nowadays, the effects of radiation and constant use of cell phones have led to some problems. These radiations cause disorders in different systems of human body and even in a growing fetus. The aim of this study was to find the effect of using cell phone and internet by pregnant women on the amount of amniotic fluid. Method: First, a questionnaire was designed and evaluated by o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista brasileira de ginecologia e obstetricia : revista da Federacao Brasileira das Sociedades de Ginecologia e Obstetricia
دوره 35 2 شماره
صفحات -
تاریخ انتشار 2013