Conception, design and development of a low-cost intelligent prosthesis for one-sided transfemoral amputees

نویسندگان

  • Wilson Carlos da Silva Júnior
  • Marco Aurélio Vinchi de Oliveira
  • Jean-Jacques Bonvent
چکیده

Introduction: Modern transfemoral knee prostheses are designed to offer comfort and self-confidence to amputees. These prostheses are mainly based upon either a passive concept, with a damping system, or an active computational intelligent design to control knee motion during the swing phase. In Brazil, most lower extremity amputees are unable to afford modern prostheses due to their high cost. In this work, we present the conception, design and development of a low-cost intelligent prosthesis for one-sided transfemoral amputees. Methods: The concept of the prosthesis is based on a control system with sensors for loads, which are installed on the amputee’s preserved leg and used as a mirror for the movement of the prosthesis. Mechanical strength analysis, using the Finite Element Method, electromechanical tests for the sensors and actuators and verification of data acquisition, signal conditioning and data transferring to the knee prosthesis were performed. Results: The laboratory tests performed showed the feasibility of the proposed design. The electromechanical concept that was used enabled a controlled activation of the knee prosthesis by the two load cells located on the shoe sole of the preserved leg. Conclusions: The electromechanical design concept and the resulting knee prosthesis show promising results concerning prosthesis activation during walking tests, thereby showing the feasibility of a reduced manufacturing cost compared to the modern prostheses available on the market.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retractable Prosthesis for Transfemoral Amputees Using Series Elastic Actuators and Force Control

We present a highly functional and cost-effective prosthesis for transfemoral amputees that uses series elastic actuators. These actuators allow for accurate force control, low impedance and large dynamic range. The design involves one active joint at the knee and a passive joint at the ankle. Additionally, the socket was designed using mirroring of compliances to ensure maximum comfort.

متن کامل

Assessment of aerobic capacity and walking economy of unilateral transfemoral amputees.

BACKGROUND Studies of the maximal oxygen uptake (VO(2max)) of transfemoral amputees have mostly used protocols that activate a relatively small muscle mass. Consequently, transfemoral amputee VO(2max) may be systematically underestimated, and the validity of these test protocols is questionable. OBJECTIVES (1) Investigate validity and reliability of a VO(2max) walking protocol and (2) compare...

متن کامل

Energy cost of walking in transfemoral amputees: Comparison between Marlo Anatomical Socket and Ischial Containment Socket.

OBJECTIVE To compare energy cost of walking (ECW) and prosthesis-related perceived mobility with the Marlo Anatomical Socket (MAS(®)) and the Ischial Containment (IC) Socket. METHOD Transfemoral (TF) amputees were enrolled in the study. ECW tests were conducted inside, in a hallway with a regular floor surface. Subjects had to walk back and forth on a 61m linear course at their own self-selec...

متن کامل

Engineering platform and experimental protocol for design and evaluation of a neurally-controlled powered transfemoral prosthesis.

To enable intuitive operation of powered artificial legs, an interface between user and prosthesis that can recognize the user's movement intent is desired. A novel neural-machine interface (NMI) based on neuromuscular-mechanical fusion developed in our previous study has demonstrated a great potential to accurately identify the intended movement of transfemoral amputees. However, this interfac...

متن کامل

Whole Body Awareness for Controlling a Robotic Transfemoral Prosthesis

Restoring locomotion functionality of transfemoral amputees is essential for early rehabilitation treatment and for preserving mobility and independence in daily life. Research in wearable robotics fostered the development of innovative active mechatronic lower-limb prostheses designed with the goal to reduce the cognitive and physical effort of lower-limb amputees in rehabilitation and daily l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015