The effect of filter size on VBM analyses of DT-MRI data.

نویسندگان

  • Derek K Jones
  • Mark R Symms
  • Mara Cercignani
  • Robert J Howard
چکیده

Voxel-based morphometry (VBM) has been used to analyze diffusion tensor MRI (DT-MRI) data in a number of studies. In VBM, following spatial normalization, data are smoothed to improve the validity of statistical inferences and to reduce inter-individual variation. However, the size of the smoothing filter used for VBM of DT-MRI data is highly variable across studies. For example, a literature review revealed that Gaussian smoothing kernels ranging in size (full width at half maximum) from zero to 16 mm have been used in DT-MRI VBM type studies. To investigate the effect of varying filter size in such analyses, whole brain DT-MRI data from 14 schizophrenic patients were compared with those of 14 matched control subjects using VBM, when the filter size was varied from zero to 16 mm. Within this range of smoothing, four different conclusions regarding apparent patient control differences could be made: (i) no significant patient-control differences; (ii) reduced FA in right superior temporal gyrus (STG) in patients; (iii) reduced FA in both right STG and left cerebellum in patients; and (iv) reduced FA only in left cerebellum in patients. These findings stress the importance of recognizing the effect of the matched filter theorem on VBM analyses of DT-MRI data. Finally, we investigated whether one of the underlying assumptions of parametric VBM, i.e., the normality of the residuals, is met. Our results suggest that, even with moderate smoothing, a large number of voxels within central white matter regions may have non-normally distributed residuals thus making valid statistical inferences with a parametric approach problematic in these areas.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of Fiber Direction in High Angular Resolution Diffusion Images using Spherical Harmonics Functions and Wiener Filter

Diffusion tensor imaging (DTI) MRI is a noninvasive imaging method of the cerebral tissues whose fibers directions are not evaluated correctly in the regions of the crossing fibers. For the same reason the high angular resolution diffusion images (HARDI) are used for estimation of the fiber direction in each voxel. One of the main methods to specify the direction of fibers is usage of the spher...

متن کامل

DT-MRI Tractography and its Application in Cognitive Neuroscience

Recent advancement of MRI techniques and development of new methods of image analysis have allowed us to study large neural tracts within the human brain. This is based on the principle of diffusion tensor MRI that is similar to that of diffusion-weighted imaging but takes magnitude and direction of the diffusion of water into account. Using this technique we have been able to define large neur...

متن کامل

DT-MRI Tractography and its Application in Cognitive Neuroscience

Recent advancement of MRI techniques and development of new methods of image analysis have allowed us to study large neural tracts within the human brain. This is based on the principle of diffusion tensor MRI that is similar to that of diffusion-weighted imaging but takes magnitude and direction of the diffusion of water into account. Using this technique we have been able to define large neur...

متن کامل

رابطه ‌کمال‌گرایی و ساختار مغز

Abstract The aim of the present study was to investigate the relationship between perfectionism, as a personality trait, and the brain structure. A total of 49 volunteers (23 women, 26 men) participated in this study by filling a Farsi version of the Positive and Negative Perfectionism Scale (FPANPS) and attending an MRI session. Voxel-based morphometry (VBM) method was used to analyze the MRI...

متن کامل

Biomedical Image Denoising Based on Hybrid Optimization Algorithm and Sequential Filters

Background: Nowadays, image de-noising plays a very important role in medical analysis applications and pre-processing step. Many filters were designed for image processing, assuming a specific noise distribution, so the images which are acquired by different medical imaging modalities must be out of the noise. Objectives: This study has focused on the sequence filters which are selected ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • NeuroImage

دوره 26 2  شماره 

صفحات  -

تاریخ انتشار 2005