Effect of orthodontic debonding and residual adhesive removal on 3D enamel microroughness
نویسندگان
چکیده
BACKGROUND Termination of fixed orthodontic treatment is associated with bracket debonding and residual adhesive removal. These procedures increase enamel roughness to a degree that should depend on the tool used. Enamel roughening may be associated with bacterial retention and staining. However, a very limited data exists on the alteration of 3D enamel roughness resulting from the use of different tools for orthodontic clean-up. AIMS 1. To perform a precise assessment of 3D enamel surface roughness resulting from residual adhesive removal following orthodontic debonding molar tubes. 2. To compare enamel surfaces resulting from the use of tungsten carbide bur, a one-step polisher and finisher and Adhesive Residue Remover. MATERIAL AND METHODS Buccal surfaces of forty-five extracted human third molars were analysed using a confocal laser microscope at the magnification of 1080× and 3D roughness parameters were calculated. After 20 s etching, molar tubes were bonded, the teeth were stored in 0.9% saline solution for 24 hours and debonded. Residual adhesive was removed using in fifteen specimen each: a twelve-fluted tungsten carbide bur, a one-step finisher and polisher and Adhesive Residue Remover. Then, surface roughness analysis was repeated. Data normality was assessed using Shapiro-Wilk test. Analysis of variance (ANOVA) was used to compare between variables of normal distribution and for the latter-Kruskal-Wallis test. RESULTS Sa (arithmetical mean height) was significantly different between the groups (p = 0, 01326); the smoothest and most repeatable surfaces were achieved using Adhesive Residue Remover. Similarly, Sq (root mean square height of the scale-limited surface) had the lowest and most homogenous values for Adhesive Residue Remover (p = 0, 01108). Sz (maximum height of the scale-limited surface) was statistically different between the groups (p = 0, 0327), however no statistically significant differences were found concerning Ssk (skewness of the scale-limited surface). DISCUSSION Confocal laser microscopy allowed 3D surface analysis of enamel surface, avoiding the limitations of contact profilometry. Tungsten carbide burs are the most popular adhesive removing tools, however, the results of the present study indicate, that a one step polisher and finisher as well as Adhesive Residue Remover are less detrimental to the enamel. This is in agreement with a recent study based on direct 3D scanning enamel surface. It proved, that a one-step finisher and polisher as well as Adhesive Residue Remover are characterized by a similar effectiveness in removing residual remnants as tungsten carbide bur, but they remove significantly less enamel. CONCLUSION Orthodontic debonding and removal of adhesive remnants increases enamel roughness. The smoothest surfaces were achieved using Adhesive Residue Remover, and the roughest using tungsten carbide bur.
منابع مشابه
Effect of Orthodontic Debonding and Adhesive Removal on the Enamel – Current Knowledge and Future Perspectives – a Systematic Review
After orthodontic treatment, brackets are debonded and residual adhesive is removed, causing iatrogenic enamel damage. The aim of this study was to review the methods of orthodontic adhesive removal, find clear evidence, and provide a rationale for this procedure. A literature search was performed in PubMed, Dentistry and Oral Sciences, Scopus, Cochrane, Google, and Google Scholar using keyword...
متن کاملEnamel Surface Roughness after Orthodontic Bracket Debonding and Composite Resin Removal by Two Types of Burs
Objective: Increased enamel surface roughness following orthodontic bracket debonding leads to increased plaque accumulation and enamel decalcification. Therefore, different methods are employed to achieve smoother enamel surfaces after bracket debonding. This study compared enamel surface roughness following orthodontic bracket debonding and composite resin removal using white stone and tung...
متن کاملThree-dimensional quantitative analysis of adhesive remnants and enamel loss resulting from debonding orthodontic molar tubes
AIMS Presenting a new method for direct, quantitative analysis of enamel surface. Measurement of adhesive remnants and enamel loss resulting from debonding molar tubes. MATERIAL AND METHODS Buccal surfaces of fifteen extracted human molars were directly scanned with an optic blue-light 3D scanner to the nearest 2 μm. After 20 s etching molar tubes were bonded and after 24 h storing in 0.9% sa...
متن کاملEffect of adhesive remnant removal on enamel topography after bracket debonding
INTRODUCTION At orthodontic treatment completion, knowledge about the effects of adhesive remnant removal on enamel is paramount. OBJECTIVE This study aimed at assessing the effect of different adhesive remnant removal methods on enamel topography (ESI) and surface roughness (Ra) after bracket debonding and polishing. METHODS A total of 50 human premolars were selected and divided into five...
متن کاملبررسی تأثیر دو نوع ادهزیو و دو نوع وسیله دی باندینگ بر میزان ادهزیو باقیمانده بر روی مینای دندان
Background and Aim: At the end of fixed orthodontic treatment, enamel damages are affected by amount of adhesive remnants. Thus, determining the factors involves in the amount of adhesive remnants e.g. the types of resins and the methods used for debonding is of necessity. The aim of this study was to evaluate the effect of the composite resin type and debonding pliers on enamel surface by a ne...
متن کامل