Sedative use during continuous positive airway pressure titration improves subsequent compliance: a randomized, double-blind, placebo-controlled trial.
نویسندگان
چکیده
BACKGROUND The initial experience with continuous positive airway pressure (CPAP) may predict subsequent compliance. In a retrospective study, we found that premedication with nonbenzodiazepine sedative-hypnotic agents during CPAP titration polysomnography independently predicted short-term compliance. To validate these findings, we conducted a prospective clinical trial to assess whether premedication with eszopiclone prior to CPAP titration would improve short-term CPAP compliance. METHODS Subjects in this randomized, double-blind, placebo-controlled trial received 3 mg of eszopiclone or matching placebo prior to undergoing CPAP titration polysomnography. We compared the quality of CPAP titrations and objective measures of compliance during the first 4 to 6 weeks of therapy between the two groups. RESULTS We enrolled 117 subjects, and 98 subjects completed the protocol (eszopiclone, 50 subjects; placebo, 48 subjects). Other than there being more women in the eszopiclone group, the groups were similar at baseline. Compared with placebo, premedication with eszopiclone significantly improved mean (+/- SD) sleep efficiency (87.8 +/- 5.8% vs 80.1 +/- 10.5%, respectively; p = 0.002) and mean total sleep time (350.9 +/- 33.6 min vs 319.7 +/- 48.7 min, respectively; p = 0.007). A trend toward improved sleep latency (19.4 +/- 16.1 min vs 31.8 +/- 30.4 min, respectively; p = 0.08) and the number of residual obstructive events observed at the final CPAP pressure (6.4 +/- 7 events/h vs 12.8 +/- 14.6 events/h, respectively; p = 0.08) during polysomnography was found. Eszopiclone significantly improved CPAP compliance. Among subjects premedicated with eszopiclone, CPAP was used on a higher percentage of nights (75.9 +/- 20.0% vs 60.1 +/- 24.3%, respectively; p = 0.005) and for more hours per night (4.8 +/- 1.5 h vs 3.9 +/- 1.8 h, respectively; p = 0.03). CONCLUSIONS Premedication with eszopiclone on the night of CPAP titration improved the quality of CPAP titration and led to significantly greater short-term compliance. TRIAL REGISTRATION ClinicalTrials.gov Identifier: NCT00507117.
منابع مشابه
Use of heated humidification during nasal CPAP titration in obstructive sleep apnoea syndrome.
Nasal symptoms associated with the use of nasal continuous positive airway pressure (nCPAP) in obstructive sleep apnoea (OSA) can adversely impact on patients' tolerance, acceptance and adherence to nCPAP therapy. Regular use of heated humidification is effective in alleviating these symptoms and improve patient comfort. In a randomised, parallel, double-blinded, controlled study, the present a...
متن کاملRadiofrequency treatment of turbinate hypertrophy in subjects using continuous positive airway pressure: a randomized, double-blind, placebo-controlled clinical pilot trial.
OBJECTIVES To estimate the treatment effect of temperature-controlled radiofrequency (TCRF) reduction of turbinate hypertrophy in patients with sleep-disordered breathing (SDB) treated with nasal continuous positive airway pressure (CPAP), and to assess the impact of study design on this estimate. STUDY DESIGN Prospective, randomized, double-blind, placebo-controlled clinical pilot trial. M...
متن کاملEarly Nasal Intermittent Positive Pressure Ventilation (NIPPV) versus Nasal Continuous Positive Airway Pressure (NCPAP) for Respiratory Distress Syndrome (RDS) in Infants of 28-36 weeks gestational age: a Randomized Controlled Trial
Background: Early nasal continuous positive airway pressure (NCPAP) has emerged as a primary modality of respiratory support for preterm infants withrespiratory distress syndrome (RDS). However, 30%-40% of these newborns need subsequent mechanical ventilation. Nasal intermittent positive pressure ventilation (NIPPV) is a promising alternative to NCPAP, especially in po...
متن کاملSudden Complete Versus Gradual Weaning from Nasal Continuous Positive Airway Pressure in Preterm Neonates: A Randomized Controlled Trial
Background: Continuous positive airway pressure (CPAP) is used as respiratory support in preterm neonates; however, the best weaning method has not yet been determined. In this study, we compared sudden complete and gradual weaning from nasal CPAP (NCPAP) in preterm newborns. Methods: This randomized controlled trial was conducted on 62 prete...
متن کاملInterventions to improve compliance in sleep apnea patients previously non-compliant with continuous positive airway pressure.
STUDY OBJECTIVES Despite widespread agreement that continuous positive airway pressure is effective therapy for obstructive sleep apnea, it is estimated that 50% of patients recommended for therapy are noncompliant 1 year later. Interventions to improve compliance in such patients have not been studied. We evaluated a 2 phase intervention program to improve compliance in sleep apnea patients pr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 136 5 شماره
صفحات -
تاریخ انتشار 2009