In vivo intravoxel incoherent motion measurements in the human placenta using echo-planar imaging at 0.5 T.

نویسندگان

  • R J Moore
  • B Issa
  • P Tokarczuk
  • K R Duncan
  • P Boulby
  • P N Baker
  • R W Bowtell
  • B S Worthington
  • I R Johnson
  • P A Gowland
چکیده

This paper presents the first in vivo measurements of intravoxel incoherent motion in the human placenta, obtained using the pulsed gradient spin echo (PGSE) sequence. The aims of this study were two-fold. The first was to provide an initial estimate of the values of the IVIM parameters in this organ, which are currently unknown. The second aim was then to use these results to optimize the sequence timings for future studies. The moving blood fraction (f), diffusion coefficient (D), and pseudo-diffusion coefficient (D*) were measured. The average value of f was 26 +/- 6 % (mean +/- SD), D was 1.7 +/- 0.5 x 10(-3) mm2/sec, and D* was 57 +/- 41 x 10(-3) mm2/sec. For the optimized values of b, the expected percentage uncertainty in the fitted values of f, D, and D* for the placenta were sigmaf/f = 14.9%, sigmaD/D = 14.3%, sigmaD*/D* = 44.9%, for an image signal-to-noise of 20:1, and a total imaging time of 800 sec.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Echo-planar imaging of intravoxel incoherent motion.

The recently established single-shot technique of echo-planar imaging of intravoxel incoherent motion (IVIM) for determining and imaging the variations of microscopic motions of water has been applied to studies of water perfusion in phantoms and to in vivo studies of diffusion and perfusion in cat and human brains. The phantom results demonstrate that perfusion levels comparable with those fou...

متن کامل

Functional Mapping of the Human Visual Cortex with Intravoxel Incoherent Motion MRI

Functional imaging with intravoxel incoherent motion (IVIM) magnetic resonance imaging (MRI) is demonstrated. Images were acquired at 3 Tesla using a standard Stejskal-Tanner diffusion-weighted echo-planar imaging sequence with multiple b-values. Cerebro-spinal fluid signal, which is highly incoherent, was suppressed with an inversion recovery preparation pulse. IVIM microvascular perfusion par...

متن کامل

MR Imaging of Intravoxel Incoherent Motions

401 Molecular diffusion and microcirculation in the capillary network resuit in a distribution of phases in a single voxel in the presence of magnetic field gradients. This distribution produces a spin-echo attenuation. The authors have developed a magnetic resonance (MR) method to image such intravoxel incoherent motions (IVIMs) by using appropniate gradient pulses. Images were generated at 0....

متن کامل

Intravoxel incoherent motion imaging using steady-state free precession.

IVIM MR imaging is a method which generates images of diffusion and perfusion in vivo. Until now, intravoxel incoherent motion (IVIM) images have been obtained using spin-echo sequences with extragradient pulses, resulting in long acquisition times (typically 2 x 8 min 32 s). A new method is proposed here, using steady-state free precession (SSFP), which allows IVIM images to be obtained in a c...

متن کامل

Non-parametric intravoxel incoherent motion analysis of the thyroid gland

PURPOSE To implement a protocol for intravoxel incoherent motion (IVIM) of the thyroid, to determine base parameters in healthy volunteers, and to provide preliminary experience on clinical applicability in one patient. MATERIALS AND METHODS Eight healthy volunteers underwent 3T MRI using a diffusion weighted echo-planar imaging sequence with 12 different b-values between 0-800 s/mm2. The IVI...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 43 2  شماره 

صفحات  -

تاریخ انتشار 2000