Fortum stability in different disposable infusion devices by pyridine assay.

نویسندگان

  • P Favetta
  • C Allombert
  • C Breysse
  • C Dufresne
  • J Guitton
  • J Bureau
چکیده

The stability of ceftazidime in 5% dextrose injection and 0.9% sodium chloride injection when stored in a different disposable infusion device was determined. Solutions of ceftazidime 40 mg/ml were used to fill the drug administration devices. Stability was determined for both 5% dextrose injection and 0.9% sodium chloride injection solutions at 37 degrees C in four disposable infusion devices. Ceftazidime and its mean degradation product, pyridine, were simultaneously assayed in triplicate by a stability-indicating high-performance liquid chromatographic (HPLC) method. This method was simple, sensitive (limit of quantitation (LOQ), 2 ng injected for both compounds), rapid (run time was 7 min) and precise (mean recovery was 100.5+/-2.9 and 103.6+/-1.9% for pyridine and ceftazidime, respectively). The ceftazidime stability in the 5% dextrose solution was lower than in the 0.9% sodium chloride solution. When stored at 37 degrees C in a disposable infusion device, the stability of the ceftazidime is included in large hourly range, depending strongly on the manufacturer. The stability of ceftazidime exceed 19 h in none studied cases. The pyridine formed in 24 h was in the range of 100-400 mg depending on devices and infusions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Stability of Etoposide Solutions in Disposable Infusion Devices for Day Hospital Cancer Practices

In a context of day hospital care of cancer patients, a protocol combining etoposide and carboplatin is used in paediatrics. Disposable infusion devices can be used to improve patient quality of life and to optimize nursing time. Stability data are available for carboplatin in these devices but not for etoposide. The aim of this study was to determine the stability of etoposide solutions in the...

متن کامل

Stability of commonly used antibiotic solutions in an elastomeric infusion device.

BACKGROUND The Accufuser silicone-based elastomeric infusion device has recently been approved for the Canadian market. OBJECTIVE To evaluate the stability of 5 antibiotics (cefazolin, ceftazidime, ceftriaxone, clindamycin, and vancomycin) in either 5% dextrose in water (D5W) or 0.9% sodium chloride in water (NS) after storage in Accufuser disposable silicone balloon infusers. METHODS The s...

متن کامل

An Observational Study of Errors Related to the Preparation and Administration of Medications Given by Infusion Devices in a Teaching Hospital

Since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (ICU). The investigation was conducted in a Teaching hospital in the form of a prospective, observational study. A sample size of 43 doses administered to ICU patients was chosen to enable reliable estimate of error ...

متن کامل

An Observational Study of Errors Related to the Preparation and Administration of Medications Given by Infusion Devices in a Teaching Hospital

Since there is no detailed hospital based incident reporting system, this study was designed to evaluate the medication errors associated with infusion pumps in intensive care unit (ICU). The investigation was conducted in a Teaching hospital in the form of a prospective, observational study. A sample size of 43 doses administered to ICU patients was chosen to enable reliable estimate of error ...

متن کامل

Disposable infusion pumps.

PURPOSE The properties, performance, and applications of nonelectric disposable infusion pumps are reviewed. SUMMARY All nonelectric disposable infusion pumps exploit the same physical principle: mechanical restriction within the flow path determines the speed of pressurized fluid. The pressure generated by disposable pumps on fluid is 250-600 mm Hg, compared with 5-1200 mm Hg of pressure for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of pharmaceutical and biomedical analysis

دوره 27 6  شماره 

صفحات  -

تاریخ انتشار 2002