A simple calf muscle ergometer for use in a standard whole-body MR scanner.

نویسندگان

  • B Quistorff
  • S Nielsen
  • C Thomsen
  • K E Jensen
  • O Henriksen
چکیده

A calf muscle ergometer, designed for use in a standard whole-body MR scanner, is described. The instrument allows isotonic or isometric calf muscle exercise over a continuous range of work loads from 0 to individual maximum work output. Work output may be recorded on a strip chart recorder. A sound encoding provides an effective guidance for the subject tested to accurately reproduce his performance in each contraction cycle at a given work load. The FID recording may be triggered from the ergometer at any point during the contraction cycle. Nonmetal materials are used for the instrument construction in order to eliminate potentially disturbing eddy currents. The force resistance of the ergometer is obtained by a combined hydraulic-pneumatic system, which is loaded by coupling to an outside source of compressed air equipped with a suitable pressure regulator. When varying the time of data sampling within a repeated 6-s contraction cycle it was found that the recorded Pi/PCr ratio remained essentially constant at low and moderate work loads. However, at work loads at or above 70% of individual Vmax a pronounced dependence of the time of sampling with the contraction cycle was observed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dynamic 31P–MRSI using spiral spectroscopic imaging can map mitochondrial capacity in muscles of the human calf during plantar flexion exercise at 7 T

Phosphorus MRSI (31 P-MRSI) using a spiral-trajectory readout at 7 T was developed for high temporal resolution mapping of the mitochondrial capacity of exercising human skeletal muscle. The sensitivity and localization accuracy of the method was investigated in phantoms. In vivo performance was assessed in 12 volunteers, who performed a plantar flexion exercise inside a whole-body 7 T MR scann...

متن کامل

Changes of Nerve - Muscle Performance of Elderly Men in Response to Whole Body Vibration

Background and Aims: Whole body vibration exercise by affecting the neuromuscular system and mechanical mechanisms increase muscles strength. This study investigated the effect of whole body vibration training on neuromuscular function of elderly men. Methods: Based on a randomized controlled trial design, 72 retired elderly men with a mean age of 73.00 ± 2.67 years participated in thisstudy. A...

متن کامل

High-Resolution Echo-Planar Spectroscopic Imaging of the Human Calf

BACKGROUND This study exploits the speed benefits of echo-planar spectroscopic imaging (EPSI) to acquire lipid spectra of skeletal muscle. The main purpose was to develop a high-resolution EPSI technique for clinical MR scanner, to visualise the bulk magnetic susceptibility (BMS) shifts of extra-myocellular lipid (EMCL) spectral lines, and to investigate the feasibility of this method for the a...

متن کامل

Comparing localized and nonlocalized dynamic 31P magnetic resonance spectroscopy in exercising muscle at 7T

By improving spatial and anatomical specificity, localized spectroscopy can enhance the power and accuracy of the quantitative analysis of cellular metabolism and bioenergetics. Localized and nonlocalized dynamic (31)P magnetic resonance spectroscopy using a surface coil was compared during aerobic exercise and recovery of human calf muscle. For localization, a short echo time single-voxel magn...

متن کامل

Implementation of quadratic dose protocol for 18F-FDG whole-body PET imaging using a BGO-based PET/CT scanner, GE Discovery ST

Introduction: The ability of quadratic dose protocol to maintain a good quality image for an overweight and obese patient is well reported. However, a practical approach to the implementation of this protocol in whole-body imaging in Malaysia is currently lacking. Hence, the aim of this study is to derive the quadratic dose formula that suits our PET system. Metho...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 13 3  شماره 

صفحات  -

تاریخ انتشار 1990