The "ultra-free" ultrafiltration technique compared with equilibrium dialysis for determination of unbound thiopental concentrations in serum.

نویسندگان

  • D Jung
  • M Mayersohn
  • D Perrier
چکیده

We compare a new ultrafiltration technique, involving a unique Millipore membrane, with the classical method of equilibrium dialysis for determining the fraction of thiopental not bound to serum proteins. This fraction, as determined by equilibrium dialysis at 37 degrees C, ranged between 12 and 16% for total concentrations at 50 microgram/L to 10 mg/L of serum. In contrast, ultrafiltration at 37 degrees C yielded a 49% higher value for unbound thiopental: 26.3 (SD 2.6)%. Determined at room temperature (24 degrees C), there was no statistically significant difference for results by the two methods: 14.2 and 15.9%, respectively. The discrepancy between results at 37 degrees C may partly be explained by serum proteins penetrating the Ultra-Free filter. For the routine clinical measurement of unbound drug concentrations, the ultrafiltration membrane at room temperature appears to be sufficiently accurate and less time-consuming than equilibrium dialysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Free serum cortisol: quantification applying equilibrium dialysis or ultrafiltration and an automated immunoassay system.

BACKGROUND Quantification of bioactive, free serum cortisol concentrations can characterize adrenocortical function more appropriately compared to total serum cortisol measurement. Ultrafiltration or equilibrium dialysis of serum samples allow direct measurement of free serum cortisol concentrations but respective methods have poorly been validated so far. The aim of our study was to investigat...

متن کامل

Simultaneous determination of free testosterone and testosterone bound to non-sex-hormone-binding globulin by equilibrium dialysis.

We describe a procedure based on equilibrium dialysis that allows the simultaneous determination of free testosterone and testosterone bound to non-sex-hormone-binding globulin (non-SHBG) in plasma. After saturating SHBG with 5 alpha-dihydrotestosterone (DHT) according to a technique recently described, the percentage of free testosterone in the treated and the untreated samples is measured by ...

متن کامل

Factors affecting the binding of disopyramide to serum proteins.

We investigated the influence of the following factors on the binding of disopyramide to serum proteins: method of drug quantification [enzyme immunoassay (EMIT) compared with liquid chromatography (HPLC)], separation technique (ultrafiltration vs equilibrium dialysis), temperature, pH, and total concentration of disopyramide. EMIT and HPLC measurements of disopyramide in ultrafiltrates prepare...

متن کامل

An improved ultrafiltration method for determining free testosterone in serum.

In this method, we use the Amicon MPS-1 centrifugal ultrafiltration device and the YMB membrane in measuring free testosterone in serum. Two independent assays are combined: total testosterone and the ultrafiltrable fraction of added [3H]testosterone. The unbound fraction is determined in 0.15-0.5 mL ultrafiltrates of 0.6 to 1 mL of variably diluted serum that has been equilibrated with [3H]tes...

متن کامل

Influence of adsorption and deproteination on potential free thyroxine reference methods.

BACKGROUND There is a need for consensus concerning reference methods to be used for calibration of commercial free-thyroxine (FT(4)) assays. METHODS Three different potential reference techniques were investigated for adsorption of T(4) to membrane materials, including any in vitro solid surfaces to which T(4) might adsorb, and for efficient separation of the T(4)-binding proteins from the f...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 27 1  شماره 

صفحات  -

تاریخ انتشار 1981