Glaucoma drainage implants: a critical comparison of types.

نویسندگان

  • Kenneth S Schwartz
  • Richard K Lee
  • Steven J Gedde
چکیده

PURPOSE OF REVIEW The purpose of this review is to critically compare the various glaucoma drainage implants in popular use. RECENT FINDINGS Glaucoma drainage implants are being increasingly utilized in the surgical management of glaucoma. Comparisons between the various drainage implants are difficult because most clinical data are derived from retrospective studies with different study populations, follow-up periods, and criteria defining success. The type of glaucoma under treatment is a major factor influencing surgical outcomes. The resistance to aqueous flow through glaucoma drainage implants occurs across the fibrous capsule around the end plate, and the major determinants of the final intraocular pressure are capsular thickness and filtration surface area. The use of antifibrotic agents as adjuncts to drainage implant surgery has not proven effective in modulating capsular thickness. Valved implants appear to reduce, but do not eliminate, the risk of hypotony. Bleb encapsulation is more frequently seen with the Ahmed valve implant than other drainage implants. Diplopia was a common complication with the Baerveldt glaucoma implant after its introduction, but design modifications have markedly reduced the incidence of this complication. SUMMARY There are several glaucoma drainage implants that are currently available, and all have been shown to be safe and effective in reducing intraocular pressure. Greater pressure reduction may be achieved with implants with larger end plates, and valved implants appear to reduce the risk of postoperative hypotony.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrospective Comparison of Intermediate-term Efficacy of 350 mm2 Glaucoma Drainage Implants and Medium-sized 230-250 mm2 Implants

AIM To compare the intermediate-term efficacy of a large surface area Baerveldt 350 mm2 glaucoma drainage device (GDD) with medium surface area implants (Baerveldt 250 mm2 and Molteno 3, 230, or 245 mm2). DESIGN This is a retrospective, nonrandomized comparative trial. MATERIALS AND METHODS A total of 94 eyes of 94 patients of mixed glaucoma diagnoses without any prior glaucoma surgical pro...

متن کامل

[Glaucoma drainage implants in the treatment of refractory glaucoma].

The authors describe their experience with the first three glaucoma drainage implants. All patients had previously several antiglaucomatous operations and a greatly reduced vision. The intraocular pressure was resistant to conservative treatment. In all patients the authors recorded postoperative complications reported in the literature. Glaucoma drainage implants extend possibilities in patien...

متن کامل

Plain film imaging of Baerveldt glaucoma drainage implants.

A glaucoma drainage implant was detected on plain skull radiographs before MR imaging examination of the brain. The patient was denied the MR imaging for fear of dislodging the "metallic foreign body." The Baerveldt glaucoma drainage implant was mistakenly identified as an orbital metallic object based on its radiographic characteristics. Because none of the current glaucoma drainage implants c...

متن کامل

Glaucoma Surgery in Pregnancy: A Case Series and Literature Review

AbstractGlaucoma management in pregnant patients is a real challenge, especially when the glaucoma is not controlled with medications. We report the results of 6 incisional glaucoma surgeries for the management of medically uncontrolled glaucoma patients during pregnancy. This retrospective, case series was conducted on the 6 eyes of 3pregnant patients with uncontrolled glaucoma using maximum t...

متن کامل

The New Era of Glaucoma Micro-stent Surgery

Minimally invasive glaucoma surgery (MIGS) has been gaining popularity over the last decade. Although there is no strict definition for MIGS, all the new procedures share the common theme of intraocular pressure reduction with minimal tissue destruction, short surgical time, simple instrumentation and fast postoperative recovery. The use of glaucoma drainage implants has long been the tradition...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Current opinion in ophthalmology

دوره 17 2  شماره 

صفحات  -

تاریخ انتشار 2006