Stent distortion after sutureless aortic valve implantation: a new complication seen with a novel surgical technique.

نویسندگان

  • Felix Fleissner
  • Ulrich Molitoris
  • Malakh Shrestha
  • Andreas Martens
چکیده

In recent years, sutureless aortic valves have grown in popularity. As these valves do not need to be anchored with sutures, shorter cardiac ischaemia and extracorporeal circulation times can potentially be achieved. In addition, the absence of a sewing ring in these valves results in a greater effective orifice area for any given size. Postoperative outcome may be improved using sutureless valves especially when combined with minimally invasive surgical techniques. However, sutureless aortic valves present unique surgical risks. We report 2 cases of delayed distortion of a sutureless aortic valve stent resulting in paravalvular leakage and increased transvalvular gradients. One patient underwent a reoperation with an aortic valve replacement using a standard biological aortic valve, the other patient was treated with balloon dilatation of the aortic valve stent.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In the era of the valve-in-valve: is transcatheter aortic valve implantation (TAVI) in sutureless valves feasible?

Sutureless aortic valve implantation has emerged as an innovative alternative for treatment of aortic stenosis. By avoiding the placement of sutures, this approach aims to improve surgical outcomes by facilitating less traumatic minimally invasive approaches and reducing cross-clamp and cardiopulmonary bypass duration. However, the absence of sutures may have detrimental effects after sutureles...

متن کامل

Perceval Sutureless Valve – are Sutureless Valves Here?

With the advent of transcatheter aortic valve implantation (TAVI) techniques, a renewed interest has developed in sutureless aortic valve concepts in the last decade. The main feature of sutureless aortic valve implantation is the speed of insertion, thus making implantation easier for the surgeon. As a result, cross clamp times and myocardial ischemia may be reduced. The combined procedures (C...

متن کامل

AN INNOVATIVE SURGIC AL TECHNIQUE FOR CONTINUOUS SUTURING OF PROSTHESIS IN MITR AL VALVE REPL A CEMENT

Mitral valve replacement (MVR) is usually performed in two methods of running and interrupted suturing. In running method, the suturing of the valve is usually with some traction on the annulus and also there is a risk of aortic valve injury. This study was conducted to evaluate a new technique for suturing to avoid these complications and decrease the time of cardiac arrest. One hundred an...

متن کامل

Total endoscopic sutureless aortic valve replacement: rationale, development, perspectives.

Transcatheter valve implantation is progressively becoming the first line option for high risk patients in the management of severe aortic valve stenosis. Surgery is likely to remain the gold standard treatment option for intermediate risk patients since it ensures ablation of the underlying pathology and the calcified aortic valvular tissue, which potentially can act as a nidus of chronic embo...

متن کامل

Three Different Imaging Modalities of a Patient with the Aortic Coarctation

The patient was a 19 year-old woman with the diagnosis of resistant hypertension, although she was under treatment of three classes of anti-hypertensive drugs (beta blocker, angiotensin receptor blocker, diuretic) for more than one year. In physical examination there was only a significant difference between the systolic blood pressure of upper and lower extremities (200 vs. 120 mmHg), without ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 2015