Hard Magnetic Material for Perpendicular Magnetic Anisotropic Field in Electromagnetic Actuator Fabrication
نویسندگان
چکیده
This paper describes a high power electromagnetic microactuator fabrication method that combines the hard magnetic Fe/Pt process, Ni/Fe permalloy magnetic circuit design, bulk micromachining, and excimer laser ablation. The hard magnetic material Fe/Pt is deposited under low temperature less than 300◦C by sputter onto a suspension diaphragm to produce a perpendicular magnetic anisotropic field. The magnetic circuit with closed loop design is applied to concentrate the magnetic flux and increase the magnetic force. The magnetic field induced by the planar coil and Ni/Fe permalloy enhances the interaction with Fe/Pt to induce attractive and repulsive displacement, provide a large output force, and operate at high frequency. This high power electromagnetic microactuator is demonstrated with minimum dimensions with a magnetic force two times greater than conventional magnetic micro-actuators.
منابع مشابه
Design and Fabrication of Helmholtz Coils to Study the Effects of Pulsed Electromagnetic Fields on the Healing Process in Periodontitis: Preliminary Animal Results
Background: Effects of electromagnetic fields on healing have been investigated for centuries. Substantial data indicates that exposure to electromagnetic field can lead to enhanced healing in both soft and hard tissues. Helmholtz coil is a device that generates pulsed electromagnetic fields. Objective: In this study, a pair of Helmholtz coils for enhancing thehealing process in periodontitis w...
متن کاملApplication of polyimide to bending-mode microactuators with Ni/Fe and Fe/Pt magnet
Out-of-plane polyimide (PI) electromagnetic microactuators with different geometries are designed, fabricated and tested. Fabrication of the electromagnetic microactuators consists of 10 lm thick Ni/Fe (80/20) permalloy deposition on PI diaphragm by electroplating process, electroplating of copper planar coil with 10 lm thick, bulk micromachining, and excimer laser selective ablation. They are ...
متن کاملPreliminary Design of a Perpendicular Biased Ferrite Loaded Accelerating Cavity
A ferrite loaded accelerating cavity with a frequency sweep of 18 to 40MHz is studied for a possible upgrade of the CERN accelerator complex. The resonance frequency of a ferrite loaded cavity shifts by applying an external magnetic bias field to the ferrite material by means of changing the relative permeability. We present the electromagnetic design of such a cavity with a special emphasis on...
متن کاملLarge-displacement Electromagnetic Actuators Using the Meander Springs Partially Exposed to Magnetic Field
We present the design, fabrication and test of a large-displacement electromagnetic actuator using the meander springs, exposed partially to magnetic field. We compare two prototypes including the conventional prototype F with the meander springs exposed fully to magnetic field and the present prototype P with the meander springs exposed partially to magnetic field. In the experimental study, t...
متن کاملElectromagnetic actuator for generating variably oriented shear waves in MR elastography.
Magnetic resonance elastography (MRE) is a recently developed technique for determining the mechanical properties of biological tissue. In dynamic MRE, electromagnetic units (actuators) are widely used to generate shear waves in tissue. These actuators exploit the interaction between the static magnetic field B(0) and an annular coil supplied with alternating currents. Therefore, coil movements...
متن کامل