Impact of Lesion Placement on Efficacy and Safety of Catheter-Based Radiofrequency Renal Denervation.

نویسندگان

  • Felix Mahfoud
  • Stefan Tunev
  • Sebastian Ewen
  • Bodo Cremers
  • Jennifer Ruwart
  • Daniel Schulz-Jander
  • Dominik Linz
  • Justin Davies
  • David E Kandzari
  • Robert Whitbourn
  • Michael Böhm
  • Robert J Melder
چکیده

BACKGROUND Insufficient procedural efficacy has been proposed to explain nonresponse to renal denervation (RDN). OBJECTIVES The aim of this study was to examine the impact of different patterns of lesion placements on the efficacy and consistency of catheter-based radiofrequency RDN in pigs. METHODS The impact of increasing number of lesions versus location of RDN was investigated in a porcine model (Group 1; n = 51). The effect of treating the main artery, the branches, and the 2 combined was compared in Group 2 (n = 48). The durability of response and safety of combined treatment of the main artery plus branches was examined in Group 3 (n = 16). Renal norepinephrine (NE) tissue content and renal cortical axon density were assessed. RESULTS Increasing the number of RF lesions (4, 8, and 12) in the main renal artery was not sufficient to yield a clear dose-response relationship on NE content and axon density. In contrast, targeted treatment of the renal artery branches or distal segment of the main renal artery resulted in markedly less variability of response and significantly greater reduction of both NE and axon density than conventional treatment of only the main renal artery. Combination treatment (main artery plus branches) produced the greatest change in renal NE and axon density with the least heterogeneity. The changes were durable through 28 days post-treatment. CONCLUSIONS These data provide the rationale for investigation of an optimized approach for RDN in future clinical studies. This may have profound implications for the clinical application of RDN, as this approach may not only achieve greater reductions in sympathetic activity but also reduce treatment effect variability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Safety and feasibility of transcatheter renal sympathetic denervation using different types of catheter and various radiofrequency settings

BACKGROUND To evaluate in vivo the feasibility and safety of renal sympathetic denervation (RSD) with different catheters and various radiofrequency protocols. METHODS AND RESULTS Twenty-two pigs were included. First 2 pigs were enrolled in a feasibility protocol using one catheter and power from 5 W to 20 W. The next 10 pigs underwent RSD with three different catheters and four different RF-...

متن کامل

Efficacy and safety of a novel multi-electrode radiofrequency ablation catheter for renal sympathetic denervation in pigs

OBJECTIVE To investigate the safety and efficacy of a self-developed novel multi-electrode radiofrequency ablation catheter (Spark) for catheter-based renal denervation (RDN). METHODS A total of 14 experimental miniature pigs were randomly divided into four groups (55°& 5-watt, 55°& 8-watt, 65°& 5-watt, and 65° & 8-watt groups). Spark was used for left and right renal artery radiofrequency ab...

متن کامل

Efficacy and safety of catheter-based radiofrequency renal denervation in stented renal arteries.

BACKGROUND In selected patients with hypertension, renal artery (RA) stenting is used to treat significant atherosclerotic stenoses. However, blood pressure often remains uncontrolled after the procedure. Although catheter-based renal denervation (RDN) can reduce blood pressure in certain patients with resistant hypertension, there are no data on the feasibility and safety of RDN in stented RA....

متن کامل

Safety and efficacy of a multi-electrode renal sympathetic denervation system in resistant hypertension: the EnligHTN I trial

AIMS Catheter-based renal artery sympathetic denervation has emerged as a novel therapy for treatment of patients with drug-resistant hypertension. Initial studies were performed using a single electrode radiofrequency catheter, but recent advances in catheter design have allowed the development of multi-electrode systems that can deliver lesions with a pre-determined pattern. This study was de...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 66 16  شماره 

صفحات  -

تاریخ انتشار 2015