[Influence of the method used to obtain pleural fluid on the determination of the Acid-base balance].
نویسندگان
چکیده
OBJECTIVE To analyze the methods used in our hospital for obtaining pleural fluid to determine the acid-base balance and to evaluate the clinical repercussions of each method. METHODS Initially we studied the methods used by physicians in our hospital to collect pleural fluid for determination of the acid-base balance. In a second phase, we performed a prospective, descriptive, comparative study with the participation of 71 patients with pleural effusions in order to compare the acid-base balance according to the technique used to obtain the fluid. RESULTS Pleural fluid was obtained using 3 methods: a) direct extraction using a heparinized syringe (group 1); b) extraction using a 20 mL syringe with subsequent aspiration from this syringe into a heparinized syringe (group 2); and c) filling a heparinized syringe from the 20 mL syringe (group 3). The only significant differences between group 1 and groups 2 and 3 were an increase in the pleural PO2 and oxygen saturation. The difference in the mean pH between groups 1 and 2 was 0.009 (95% confidence interval: -0.39 to 0.02; P=.5) and between groups 1 and 3 was 0.007 (95% confidence interval: -0.38 to 0.023; P=.6). The correlations between findings for PO2, pH, and PCO2 obtained in the different groups were statistically significant, with values superior to .95 in the last 2 variables. CONCLUSIONS Physicians who perform thoracentesis in our hospital use different methods for obtaining fluid to determine the pleural acid-base balance. The 3 methods analyzed show no significant differences with regard to pH or PCO2. Pleural fluid may be obtained by a single puncture with a large-volume syringe, subsequently transferring the fluid to a heparinized syringe without this significantly affecting the pH or PCO2, thus reducing the number of manipulations and the risk of complications.
منابع مشابه
Preconcentration of Pb(II) by Graphene Oxide with Covalently Linked Porphyrin Adsorbed on Surfactant Coated C18 before Determination by FAAS
A simple, highly sensitive, accurate and selective method for determination of trace amounts of Pb(II) in water samples is presented. A novel Graphene oxide with covalently linked porphyrin solid-phase extraction adsorbent was synthesized by covalently linked porphyrin onto the surfaces of graphite oxides. The stability of a chemically (GO-H2P) especially in concentrated hydrochloric acid was s...
متن کاملPreconcentration of Pb(II) by Graphene Oxide with Covalently Linked Porphyrin Adsorbed on Surfactant Coated C18 before Determination by FAAS
A simple, highly sensitive, accurate and selective method for determination of trace amounts of Pb(II) in water samples is presented. A novel Graphene oxide with covalently linked porphyrin solid-phase extraction adsorbent was synthesized by covalently linked porphyrin onto the surfaces of graphite oxides. The stability of a chemically (GO-H2P) especially in concentrated hydrochloric acid was s...
متن کاملDiagnostic Value of Measurement Specific Gravity by Refractometric and Dipstick Method in Differentiation between Transudate and Exudate in Pleural and Peritoneal Fluid
Background: Accumulation of pleural and peritoneal fluid is seen in some diseases. In order to diagnose the disease and start the treatment, one of the most important actions will be to differentiate between exudates and transudates. The objective of this study was to determine the diagnostic value of measuring the specific gravity of the fluid through...
متن کاملDetermination of L- Ascorbic Acid in Plasma by Voltammetric Method
Voltammetric techniques have been considered as important methods among the analytical techniques used for the identification and determination of trace concentrations of many biological molecules such as L-ascorbic acid (AA). L-ascorbic acid is an electro-active molecule, though it is difficult to determine its value directly with a majority of electrodes made of carbon and transition metals, ...
متن کاملA novel bedside technique for differentiation of exudative from transudative pleural effusion
Abstract Background: At present, differentiation between exudative and transudative pleural effusion is based solely on laboratory measures and is time-consuming. Asimple bedside method would be of great help to differentiate between these two types of effusions. We present a new method for this purpose assessed in 46 patients. Methods: Standard laboratory tests and our method were tested...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archivos de bronconeumologia
دوره 44 8 شماره
صفحات -
تاریخ انتشار 2008