Numerical simulation on the effects of drug eluting stents at different Reynolds numbers on hemodynamic and drug concentration distribution

نویسندگان

  • Yu Chen
  • Yan Xiong
  • Wentao Jiang
  • Fei Yan
  • Meng Guo
  • Qingyuan Wang
  • Yubo Fan
چکیده

BACKGROUND The changes of hemodynamics and drug concentration distribution caused by the implantation of drug eluting stents (DESs) in curved vessels have significant effects on In-Stent Restenosis. METHODS A 3D virtual stent with 90° curvature was modelled and the distribution of wall shear stress (WSS) and drug concentration in this model were numerically studied at Reynolds numbers of 200, 400, 600, 800. RESULTS The results showed that (1) the intensity of secondary flow at the 45° cross-section was stronger than that at the 90° cross-section; (2) As the Reynolds number increases, the WSS decreases. When the Reynolds number reaches 600, the low-WSS region only accounts for 3% of the total area. (3) The effects of Reynolds number on drug concentration in the vascular wall decreases in proportionally and then the blood velocity increased 4 times, the drug concentration in the vascular wall decreased by about 30%. (4) The size of the high drug concentration region is inversely proportional to the Reynolds number. As the blood velocity increases, the drug concentration in the DES decreases, especially at the outer bend. CONCLUSIONS It is beneficial for the patient to decrease vigorous activities and keep calm at the beginning of the stent implantation, because a substantial amount of the drug is released in the first two months of stent implantation, thus a calm status is conducive to drug release and absorption; Subsequently, appropriate exercise which increases the blood velocity is helpful in decreasing regions of low-WSS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries

Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...

متن کامل

A three-dimensional mathematical model for drug delivery from drug-eluting stents

Current drug-eluting stent (DES) technology is not optimized with regard to the pharmacokinetics of drug release, more research on the <span style="font-size: 12pt; color: #000000; font-style: normal; ...

متن کامل

On the Role of Luminal Flow and Interstrut Distance in Modelling Drug Transport from Half-Embedded Drug-Eluting Stent

A model for investigating the transport of drug from a half-embedded drug-eluting stent (DES) is developed. Keeping the relevance of the physiological situation in view, the luminal drug transport is considered as an unsteady convection-diffusion process, while the drug transport within the arterial tissue is supposed to commence as a diffusion process. The Marker and Cell (MAC) method has been...

متن کامل

Effect of static magnetic field on the hemodynamic properties of blood flow containing magnetic substances

The use of magnetic fields in targeted drug delivery, especially for treatment of cancers and tumoral regions, is one of the significant techniques in the field of modern methods of treatment. Considering that many vital biological tissues have been located deep in the body, then for targeted drug delivery and effective treatment in these tissues, it is required to bring therapeutic agent to th...

متن کامل

Numerical Simulation of Fluid Flow over a Ceramic Nanoparticle in Drug Delivery System

In this work, for better understanding of drug delivery systems, blood flow over a ceramic nanoparticle is investigated through microvessels. Drug is considered as a nanoparticle coated with the rigid ceramic. Due to the low characteristic size in the microvessel, the fluid flow is not continuum and the no-slip boundary condition cannot be applied. To solve this problem lattice Boltzmann method...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2015