Controlled comparison of a new Becton Dickinson agar slant blood culture system with Roche Septi-Chek for the detection of bacteremia and fungemia.

نویسندگان

  • L G Reimer
  • L B Reller
  • S Mirrett
چکیده

Two commercially available agar slide blood culture systems, Septi-Chek (Roche Diagnostics, Div. Hoffmann-La Roche Inc., Nutley, N.J.) and VACUTAINER agar slant (Becton Dickinson [BD] Vacutainer Systems, Rutherford, N.J.), were compared in 5,628 paired blood cultures from adult patients. The systems were inoculated with equal volumes (5 ml) of blood. There was no statistically significant difference between the two systems in the overall recovery of clinically important microorganisms; however, significantly more Escherichia coli (P less than 0.05) organisms were detected in the Septi-Chek system. Concurrently, significantly more contaminants (P less than 0.001) also were present in Septi-Chek bottles. When microorganisms grew in both systems, there was no significant difference in the time to recovery of important organisms, except that anaerobes were detected more quickly in the BD system. This study suggests that the BD VACUTAINER agar slant is an acceptable alternative to the Septi-Chek system for routine blood cultures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Controlled evaluation of the agar-slide and radiometric blood culture systems for the detection of bacteremia and fungemia.

A commercially available agar-slide blood culture bottle (Septi-Chek; Roche Diagnostics, Div. Hoffman-La Roche, Inc., Nutley, N.J.) was compared with the radiometric blood culture system (BACTEC; Johnston Laboratories, Inc., Towson, Md.) in 8,544 paired blood cultures from adult patients. The systems were inoculated with equal volumes (10 ml) of blood. Overall, there was no statistically signif...

متن کامل

Effect of agitation and frequent subculturing on recovery of aerobic and facultative pathogens by Roche Septi-Chek and BACTEC blood culture systems.

The positivity rate and time to recovery of pathogens were compared in Roche Septi-Chek (RSC-TSB) and BACTEC radiometric systems on 3,539 paired blood cultures. Both systems were steadily agitated, with frequent subculturing or processing of the RSC-TSB agar slides and BACTEC bottles, respectively, during the first 24 h of incubation. The RSC-TSB system recovered 249 pathogens (7.0% positivity ...

متن کامل

Controlled evaluation of BACTEC Plus 26 and Roche Septi-Chek aerobic blood culture bottles.

Blood culture bottles that accept up to 10 ml of blood have recently been introduced for the BACTEC nonradiometric blood culture system. The new formulation, designated BACTEC Plus, contains 25 ml of tryptic soy broth, 0.05% sodium polyanetholesulfonate, and mixed resins. In a collaborative study conducted at three university hospitals, we evaluated the BACTEC Plus 26 (BP26) aerobic bottle and ...

متن کامل

Comparison of the Bactec Peds Plus pediatric blood culture vial with Roche pediatric Septi-Chek for blood cultures from pediatric patients.

Equal volumes of blood from 4,112 blood cultures were inoculated into one Bactec Peds Plus bottle and one Roche Septi-Chek bottle. There were no significant differences in the recoveries of bloodstream pathogens. Initial detection occurred earlier with Bactec Peds Plus, while growth on solid media occurred earlier with Roche Septi-Chek.

متن کامل

Comparison of BACTEC MYCO/F LYTIC and WAMPOLE ISOLATOR 10 (lysis-centrifugation) systems for detection of bacteremia, mycobacteremia, and fungemia in a developing country.

In less-developed countries, studies of bloodstream infections (BSI) have been hindered because of the difficulty and costs of culturing blood for bacteria, mycobacteria, and fungi. During two study periods (study period I [1997] and study period II [1998]), we cultured blood from patients in Malawi by using the BACTEC MYCO/F LYTIC (MFL), ISOLATOR 10 (Isolator), Septi-Chek AFB (SC-AFB), and Sep...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 27 12  شماره 

صفحات  -

تاریخ انتشار 1989