Prosthetic valve endocarditis due to Neisseria mucosa.

نویسندگان

  • A Coeurderoy
  • J L Avril
  • P Andre
  • F Cartier
چکیده

Non-gonococcal non-meningococcal Neisseria sp. normally inhabits the upper respiratory tract in human beings. There are four recognized species within the genus: N. sicca, N. mucosa, N. subflava and N. flavescens. They have low pathogenicity. Among them, Neisseria mucosa and N. sicca have been described to cause endocarditis. To our knowledge, this is the fourth reported case of prosthetic valve endocarditis due to Neisseria mucosa (1, 2, and 5). Our case fulfills the Modified Duke criteria for prosthetic valve endocarditis. As per our search of literature this is the fourth case of prosthetic valve endocarditis due to Neisseria mucosa (2, 3, and 6). Oral cavity is the usual source of Neisseria mucosa endocarditis. The patient in our case never had a dental procedure done after the valve replacement in 1997, but the dental plaques seen in oral cavity examination could have been the source. Neisseria mucosa endocarditis has been treated with different cidal antibiotics, the usual combination being penicillin and an amino glycoside. The indication for surgical intervention of prosthetic valve endocarditis according to ACC/AHA guidelines is heart failure, dehiscence seen by fluoroscopy or echocardiography, evidence of increasing valve obstruction or worsening regurgitation, or complications such as abscess formation (Class I evidence). In this case, the patient was sent for the valve replacement because of episodes of hypotension, the size of the vegetation, and the erythema and swelling of the left foot, which was thought to be secondary to embolic or immunologic phenomenon. A 56-year-old male with a past medical history of aortic valve replacement in 1997 with St. Jude mechanical prosthesis was brought in by EMS for evaluation of dizziness and weakness. The patient was working in a factory when he felt dizzy and fell down, but denied loss of consciousness, urinary or bowel incontinence. The patient was admitted with an impression of near syncope. On admission vital signs were stable, no orthostasis, afebrile but blood work showed WBC count of 17.4; so blood cultures were drawn. Chest X-ray did not show acute infiltrate. Echocardiogram showed EF of 37%, mildly dilated left atrium and left ventricle, akinesis of inferior/posterior and apical walls of left ventricle and prosthetic aortic valve with a peak gradient of 28mmHg. Holter study was unremarkable. The patient was discharged on his home medications. Four days later, the patient was called back as the blood cultures drawn on admission were growing Neisseria sps, non-gonococcal, non-meningococcal. On this admission the patient complained of tactile fever at home. In ER, patient’s temperature was 103.8F and blood pressure of 138/60 mmHg. The patient was admitted to the intensive care unit for monitoring with the impression of rule out prosthetic valve endocarditis. In the intensive care unit he had episodes of hypotension, which responded to fluid boluses. Infectious disease consult was done, 3 more sets of blood cultures were drawn and the patient was treated with vancomycin, gentamycin and ceftriaxone. Cardiology was consulted and performed transesophageal echocardiography which showed a mobile vegetation on the prosthetic aortic valve measuring approximately 10 × 7 mm with trace AR, no thrombus and no intracardiac shunt. Repeat blood cultures again grew Neisseria sps, non-gonococcal, non-meningococcal and antibiotics were changed to penicillin and gentamycin. Two days later, the patient complained of erythema and swelling of his left foot (picture below). MRI brain with contrast and CT scan of abdomen and pelvis were done, which did not show embolic phenomenon or any other source of infection. Dental exam of the oral cavity showed accumulated lingual plaques, which could have been the source of septicemia. Repeat blood cultures were negative. Previous blood culture samples sent to the Department of Health proved the organism to be Neisseria mucosa. The patient was transferred to New York Presbyterian Hospital for replacement of the valve. While at New York Presbyterian Hospital, he underwent a CT angiogram to evaluate his coronary arteries which revealed no evidence of significant coronary artery disease but did reveal an aortic valve mass, measuring 1.1× 0.4 cm, consistent with vegetation. The patient underwent aortic valve replacement. The removed prosthetic aortic valve was sent for pathological examination, which showed 0.5×0.2 × 0.2 cm fragment of adherent fibrinopurulent material. A gram stain was negative for the bacteria. 1. Coeurderoy A, Avril JL, Andre P, Cartier F. Prosthetic valve endocarditis due to Neisseria mucosa. J Infect. 1986 Jan;12(1):87-8 2. Hennessey R, Reinhart JH, McGuckin MB. Endocarditis caused by Neisseria mucosa in a patient with a prosthetic heart valve. Am J Med Technol. 1981 Nov;47(11):909-11 3. Tronel H, Chaudemanche H, Pechier N, Doutrelant L, Hoen B. Endocarditis due to Neisseria mucosa after tongue piercing. Clin Microbiol Infect. 2001 May;7(5):275-6. 4. Ingram RJ, Cornere B, Ellis-Pegler RB. Endocarditis due to Neisseria mucosa: two case reports and review. Clin Infect Dis. 1992 Aug;15(2):321-4. Review 5. Anderson MD, Miller LK. Endocarditis due to Neisseria mucosa. Clin Infect Dis. 1993 Jan;16(1):184 6. Dowling JN, Lee Ws, Sacco RJ, Ho M. Endocarditis caused by Neisseria mucosa in Marfan's syndrome.Ann Intern Med. 1974 Nov;81(5):641-3. 7. Fainstein V, Musher DM, Young EJ. Purulent pericarditis due to Neisseria mucosa. Chest. 1978 Oct;74(4):476-7. 8. Davis CL, Towns M, Henrich WL, Melby K. Neisseria mucosus endocarditis following drug abuse. Case report and review of the literature. Arch Intern Med. 1983 Mar;143(3):583-5. Review 9. Bacon AE 3rd , Pal PG, Schaberg DR. Neisseria mucosa endocarditis. J Infect Dis. 1990 Nov;162(5):1199-201 10.Giles MW, Andrew JH, Tellus MM. A case of polymicrobial infective endocarditis involving Neisseria mucosa occurring in an intravenous drug abuser. Aust N Z J Med. 1988 Dec;18(7):874-6 Though Neisseria mucosa has low pathogenicity, it can cause systemic infections and should be considered in the differential of organisms causing prosthetic valve endocarditis Redness of the left foot most likely secondary to embolic versus immunologic phenomenon INTRODUCTION

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prosthetic valve endocarditis caused by multidrug-resistant Candida albicans in a patient with myelodysplasia syndrome: A case report and literature review

Background and Purpose: Candida endocarditis is an infrequent disease with a high mortality rate, which commonly occurs in immunosuppressed patients with cardiac valve replacement. We reported a 70-year-old woman diagnosed with Candida prosthetic valve endocarditis (PVE). This study also involved a review of all published cases of Candida PVE from 1970. Case report: Herein, we reported a 70-ye...

متن کامل

A rare case of prosthetic aortic valve endocarditis complicated with multiple fistula to peri aortic structure

  Multiple aorto-cardiac cavity communications is very rare but important complication of prosthetic aortic valve endocarditis. The case below illustrates multiple aorto-cardiac cavity fistula formation following prostethic aortic valve endocarditis presented with slowly progressive symptoms of heart failure. A brief review of surgical reconstruction and the existing literature are presented, i...

متن کامل

Prosthetic valve endocarditis due to Neisseria skkuensis, a novel Neisseria species.

We describe the first reported case of endocarditis due to Neisseria skkuensis. The organism from the blood cultures taken on admission day was identified initially as unidentified Gram-negative cocci by Vitek2. Finally, it was identified as Neisseria skkuensis by 16 rRNA gene sequence analysis.

متن کامل

Tricuspid Valve Endocarditis in an Intravenous Drug Abuser: A Case Report

Recently, there have been more reports of cardiac valve infections due to the increasing number of intravenous (IV) drug abusers and chronic renal failure patients. Among cardiac valves, tricuspid valve is most commonly affected in the course of endocarditis. Appropriate management of these patients is a challenging and controversial issue in the field of cardiac surgery. Treatment options in s...

متن کامل

Detection of extra-cardiac hypermetabolic foci by [18F]FDG PET/CT in case of infective endocarditis and post antibiotic therapy response assessment

The diagnosis of prosthetic valve endocarditis continues to present a diagnostic challenge, due to the lower sensitivity of the modified Duke criteria and a higher percentage of negative or inconclusive echocardiography results. Diagnostic delay might result in significant morbidity/mortality. Imaging modalities like 2-[18F]fluoro-2-deoxy-D-glucose positron emission tomography/comput...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of infection

دوره 12 1  شماره 

صفحات  -