Sensitivity and rapidity of blood culture bottles in the detection of cornea organ culture media contamination by bacteria and fungi.
نویسندگان
چکیده
AIMS To test the bactericidal activity of standard organ culture medium, and to compare the sensitivity and rapidity of blood culture bottles with conventional microbiological methods for detection of bacteria and fungi inoculated in a standard cornea organ culture medium. METHODS The bactericidal activity of contaminated standard organ culture medium containing 100 IU/ml penicillin, 0.1 mg/ml streptomycin, and 0.25 micro g/ml amphotericin B was evaluated after 48 hours of incubation at 31 degrees C with five inocula of 14 bacteria. Two yeasts (Candida spp) and one Aspergillus were also tested. Contaminated media were then inoculated in three blood bottles (aerobic, anaerobic, fungal) placed in a Bactec 9240 automat; three conventional microbiological broths were the control. Changes in colour of organ culture medium and growth on conventional broth were screened daily by visual inspection. The sensitivity and rapidity of detection of contamination were compared between the three methods: blood bottle, conventional, and visual. RESULTS Organ culture medium eradicated five bacteria irrespective of the starting inoculums: Streptococcus pneumoniae, Branhamella catarrhalis, Escherichia coli, Propionibacterium acnes, and Haemophilus influenzae. For micro-organisms where the medium was ineffective or bactericidal only (methicillin resistant Staphylococcus aureus, methicillin sensitive Staphylococcus aureus, Staphylococcus epidermidis, Staphylococcus haemolyticus, Pseudomonas aeruginosa, Acinetobacter baumannii, Bacillus subtilis, Klebsiella pneumoniae, Enterococcus faecalis, Candida albicans, Candida kruzei, Aspergillus fumigatus), the blood bottle, conventional, and visual methods detected microbial growth in 100%, 76.5%, and 70% of cases respectively. Mean detection time using blood bottles was 15.1 hours (SD 13.8, range 2-52). In cases of detection by the blood bottle method and the conventional method, the former was always faster: 95.5% against 65.2% detection within 24 hours (p=0.022) respectively. CONCLUSIONS Blood bottles detect more efficiently and more rapidly a wider range of bacteria and fungi than the conventional microbiological method and the visual inspection of organ culture media.
منابع مشابه
Efficiency of blood culture bottles for the fungal sterility testing of corneal organ culture media.
BACKGROUND/AIM The consequences of fungal contamination of an organ cultured cornea, though exceptional, are often disastrous for the recipient. Consequently, eye banks often quarantine corneas for 10 days or more before passing them for grafting. This period, though detrimental to the endothelial cell density of the delivered cornea, is necessary to detect contamination using conventional micr...
متن کاملDetection of Salmonella spp contamination of carcasses slaughtered in poultry abattoir in Mashhad, Iran
A total of 60 neck skin swab samples were taken from 12 different broiler flocks after the chilling stage of processing at a commercial broiler slughtering facility in Mashhad. The presence of Salmonella was assessed by conventional culture method and confirmed by using poly O and poly H antiserum in serotyping. PCR amplification of invA gene as a specific method for detection of Salmonella w...
متن کاملتشخیص بروسلوز با استفاده از سیستم کشت خون BACTECو تائید نتایج آن با PCR
Abstract: Brucellosis is one of the most common zoonotic diseases in Iran. Growth of Brucella is slow and blood cultures of these bacteria are time-consuming via classical methods. We try to evaluate BACTEC 9120 system capacity in order to detect of bacteremia due to Brucella spp and to confirm isolated bacteria by PCR. Blood culture sample of 102 suspected patients evaluated by BACTEC 9120 sys...
متن کاملClinical laboratory comparison of a slide blood culture system with a conventional broth system.
The recovery of bacteria and fungi from blood cultures was compared in conventional tryptic soy broth (TSB) bottles and in TSB bottles with an agarcoated slide attachment. A total of 2,662 sets of blood cultures, including 413 that were positive (15.5%), were evaluated. Significantly more gram-positive and gram-negative bacteria were recovered in the slide culture bottles than in conventional b...
متن کاملClinical laboratory comparison of the 10-ml isolator blood culture system with BACTEC radiometric blood culture media.
The efficiency of the 10-ml Isolator (E. I. du Pont de Nemours & Co., Inc.) for recovery of pathogens from blood was compared with that of BACTEC 6B and 7C media (Johnston Laboratories) by using 4,195 cultures from 1,662 patients. During the first phase of the study, BACTEC bottles were inoculated with 3 ml of blood; in the second phase, bottles were inoculated with 5 ml. The objectives were to...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The British journal of ophthalmology
دوره 86 12 شماره
صفحات -
تاریخ انتشار 2002