Relative intensity correction of Raman spectrometers: NIST SRMs 2241 through 2243 for 785 nm, 532 nm, and 488 nm/514.5 nm excitation.
نویسندگان
چکیده
Standard Reference Materials SRMs 2241 through 2243 are certified spectroscopic standards intended for the correction of the relative intensity of Raman spectra obtained with instruments employing laser excitation wavelengths of 785 nm, 532 nm, or 488 nm/514.5 nm. These SRMs each consist of an optical glass that emits a broadband luminescence spectrum when illuminated with the Raman excitation laser. The shape of the luminescence spectrum is described by a polynomial expression that relates the relative spectral intensity to the Raman shift with units in wavenumber (cm(-1)). This polynomial, together with a measurement of the luminescence spectrum of the standard, can be used to determine the spectral intensity-response correction, which is unique to each Raman system. The resulting instrument intensity-response correction may then be used to obtain Raman spectra that are corrected for a number of, but not all, instrument-dependent artifacts. Peak area ratios of the intensity-corrected Raman spectrum of cyclohexane are presented as an example of a methodology to validate the spectral intensity calibration process and to illustrate variations that can occur in this measurement.
منابع مشابه
Optical properties of human normal small intestine tissue determined by Kubelka-Munk method in vitro.
AIM To study the optical properties of human normal small intestine tissue at 476.5 nm, 488 nm, 496.5 nm, 514.5 nm, 532 nm, 808 nm wavelengths of laser irradiation. METHODS A double-integrating-sphere system, the basic principle of measuring technology of light radiation, and an optical model of biological tissues were used in the study. RESULTS The results of measurement showed that there ...
متن کاملHighly resolved luminescence measurements for traces of 1,3-dibetanato europium(III) and terbium(III) complexes using a microscope laser Raman spectrometer toward the forensic discrimination.
The emission spectra of luminescent trivalent europium (Eu3+) and terbium (Tb3+) complexes were measured using a microscope laser Raman spectrometer with a doubled Nd:YAG laser (532 nm) and an Ar laser (488 nm). Excitation at 532 and 488 nm corresponded to wavelengths of the 7F1 --> 5D1 band of Eu3+ and the 7F6 --> 5D4 band of Tb3+, respectively. The Eu3+ and Tb3+ complexes were discriminated b...
متن کاملOptimization of silver nanoparticles for surface enhanced Raman spectroscopy of structurally diverse analytes using visible and near-infrared excitation.
Several experimental parameters affecting surface enhanced Raman (SER) signals using 488, 785 and 1064 nm excitation for eight diverse analytes are reported. Citrate reduced silver colloids having average diameters ranging from 40 ± 10 to 100 ± 20 nm were synthesized. The nanoparticles were characterized by transmission electron microscopy, dynamic light scattering and absorbance spectrophotome...
متن کاملRaman spectra of Ge/Ge isotope heterostructures with argon 488 and 514.5 nm excitations
Raman spectra of Ge/Ge isotope bi-layer structures recorded with 488 and 514.5 nm Ar laser excitations are reported. The relative amplitudes of the Ge and Ge confined optical phonon peaks differ significantly for the two excitations at T 1⁄4 10K, while it is almost the same for the spectra recorded at 300K. Possible interpretations of our results are provided considering the laser penetration d...
متن کاملPolarization Dependence of Surface Enhanced Raman Scattering on a Single Dielectric Nanowire
Our measurements of surface enhanced Raman scattering (SERS) on Ga2O3 dielectric nanowires (NWs) core/silver composites indicate that the SERS enhancement is highly dependent on the polarization direction of the incident laser light. The polarization dependence of the SERS signal with respect to the direction of a single NW was studied by changing the incident light angle. Further investigation...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Applied spectroscopy
دوره 61 2 شماره
صفحات -