Effects of Anterior Interbody Cages on Lumbar Foraminal Dimensions

نویسندگان

  • McGrady
  • Rao
چکیده

INTRODUCTION: Anterior lumbar interbody fusion (ALIF) using threaded cages has been shown to reduce segmental motion and restore the disc space. The effectiveness of these stand-alone cages in restoration and maintenance of intervertebral foramens has received little attention. Foraminal height reduces an average of 6.5 mm following disc removal, and interbody cages may indirectly increase and stabilize foraminal dimensions by restoring disc height in patients with degenerative disc disease. A few studies have addressed the influence of disc space distraction on the dimensions of the neuroforamen, either with interbody cages, or posterior instrumentation. To our knowledge there has been no prior investigation of foraminal space changes following implantation of tapered cages, which exhibit distinctly different geometry from the cylindrical cages. Also, the effectiveness of ALIF cages in maintaining foraminal space under dynamic loading conditions has received little attention. The objectives of this study were to investigate the effects of anterior implantation of threaded cylindrical and tapered interbody cages on: 1) morphology of the lumbar neuroforamen and 2) maintenance of foraminal dimensions under dynamic loading in flexion, extension, and lateral bending. METHODS: Sixteen fresh lumbar spine specimens (L2-L5) from bovine calf were obtained for the study. The L5 vertebra of the specimen was potted in dental cement with a loading ring mounted to the L2 vertebral body. The specimens were randomly assigned to two ALIF groups: one received two tapered lumbar cages (LT-cages, MSD, Memphis, TN) and the other received two cylindrical lumbar cages (Ray TFC/Unite system, Stryker Spine, Allendale, NJ). The techniques of cage insertion followed the recommendations of the manufacturers, and consisted of anterior discectomy, sequential annulus distraction using sized distraction spacers, followed by reaming, tapping, and insertion of the cages. Similar sized implants were used in all tested specimens (LTcages: 14–17.5mm by 21mm; Ray TFC/United: 14mm by 21mm). Pure moment of 8.5 Nm was applied to the spine in four directions: flexion, extension, and left and right lateral bending. Intervertebral motion of the ALIF segment (L3-L4) was recorded and analyzed with a motion analysis system. To measure the intervertebral foramen space, instant molding compound was carefully molded into the intervertebral foraminal space on both sides, and allowed to cure for one minute. The narrowest cross-section along the mold tangential to the neuroforamen passage was identified, and the mold was sectioned through this plane. A cross-sectional imprint of the foramen in this plane was created with an ink pad. The foraminal height and cross-sectional area were quantified from the imprints through a digital imaging system. Two sets of bilateral foraminal molds were obtained when the spine was in neutral unloaded position, one from the intact spine and one following cage implantation. To track the foraminal height deformations in response to each step of loading, four of the reflective markers used in tracking intervertebral motion were mounted on the superior and inferior bony edges of bilateral foraminal spaces. An algorithm was developed based on rigid body kinematic theory to calculate the amount of height changes. Nonparametric paired comparisons were conducted to compare the differences between the two cage groups. RESULTS SECTION: Foraminal Dimensions in Neutral Position: Results of instant molding in the unloaded neutral position showed that the median area of the narrowest cross-section of the foramen increased from 190.8mm (intact) to 224.5mm (with cages), or 17.0% increase (p<0.0005) for the tapered cage, and from 168.0 to 194.2mm, or 16.5% increase (p<0.0005) for the cylindrical cage. The median value for the maximum foraminal height increased from 22.0 to 24.7mm (or 9.8% increase, p<0.0004) for the tapered cage and from 21.3 to 23.1mm (or 8.8% increase, p<0.0004) for the cylindrical cage. There was no statistically significant difference in either foraminal dimension between the two cage types. Foraminal Height Change under Dynamic Loading: Loading in flexion produced bilateral height increase of the foramens, and loading in extension produced bilateral height decrease of the foramens. Lateral bending caused height increase of the foramen on the convex side and height decrease on the concave side. The maximum deformations of the foraminal height in response to loading in each direction for the intact spines and after cages implantation are presented in Figs.1a and 1b. Significant reduction in foraminal deformation was observed after ALIF with cages in all loading directions and with both cage types. The amounts of reduction in foraminal height deformation with cages were normalized with respect to foraminal height deformation of the intact spine (Table 1). The cylindrical cages provided significantly more stabilization of the foraminal height than the tapered cages in flexion (74.0% vs. 18.2%, p<0.03), and marginally more stabilization in the concave side of the lateral bending (69.4% vs. 62.9%, p<0.059). Fig. 1a. Normalized foraminal height deformation for the

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MRI Measurement of Neuroforaminal Dimension at the Index and Supradjacent Levels after Anterior Lumbar Interbody Fusion: A Prospective Study

BACKGROUND Anterior interbody fusion has previously been demonstrated to increase neuroforaminal height in a cadaveric model using cages. No prior study has prospectively assessed the relative change in magnetic resonance imaging (MRI) demonstrated neuroforaminal dimensions at the index and supradjacent levels, after anterior interbody fusion with a corticocancellous allograft in a series of pa...

متن کامل

Is one cage enough in posterior lumbar interbody fusion: a comparison of unilateral single cage interbody fusion to bilateral cages.

Posterior lumbar interbody fusion (PLIF), as recommended with bilateral lumbar interbody cages and pedicle screw fixation, has increased the successful fusion rate to nearly 100%. Presently, a unilateral approach to the disc space with a variant of PLIF, the trans-foraminal interbody fusion is often used. There are few clinical studies of unilateral interbody fusion. The clinical and fusion res...

متن کامل

Interbody Fusion in Low Grade Lumbar Spondylolsithesis: Clinical Outcome Does Not Correalte with Slip Reduction and Neural Foraminal Dimension.

STUDY DESIGN Prospective nonrandomized study. PURPOSE To find a possible correlation between clinical outcome and extent of lumbar spondylolisthesis reduction. OVERVIEW OF LITERATURE There is no consensus in the literature concerning whether a beneficial effect of reduction on outcome can be expected following reduction and surgical fusion for low grade lumbar spondylolisthesis. METHODS F...

متن کامل

Stability After Anterior Lumbar Fusion with Interbody Cages: A Radiostereometric Evaluation

Background: Interbody cage stabilization as a stand-alone procedure in lumbar spine fusion is questioned due to inconsistent mechanical effects registered in human cadaveric studies. Even segmental mobility exceeding the normal range of motion is described after cage implantation. For the anterior interbody cage fusion, this potential, undesired destabilization is explained by the resection of ...

متن کامل

Feasibility of manufacturing a patient-specific spinal implant

BACKGROUND CONTEXT: Lateral approach to lumbar fusion has been gaining popularity in recent years. It utilises a retroperitoneal transpsoas approach to reach the disc space in a minimally invasive fashion. It allows better access for disc clearance and insertion of large foot print cages. PURPOSE: To compare radiographic and clinical results following lateral lumbar interbody fusion (LLIF) and ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006