چکیده

We set up an electronic gradiometer for magnetocardiography (MCG) in an unshielded environment. The electronically balanced gradiometer consists of high-temperature radio-frequency superconducting quantum interference device (rf SQUID) magnetometers. The rf SQUID magnetometers are arranged to form the electronic first-order, four-vector gradiometer, or second-order gradiometer. The output of the MCG signal was filtered by a band pass (1–30 Hz) and power line filters. We can reduce the noise to ∼1 pT Hz−1/2 at 1 Hz for second-order or four-vector gradiometers. Two-dimensional MCG imaging is demonstrated. The results are discussed with data measured in the moderate magnetically shielded environment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Superconducting Quantum Interference Device: The Most Sensitive Detector of Magnetic Flux

SQUIDs are the most sensitive devices in detecting the magnetic flux. The devices have been used to detect small magnetic field, current, voltage, inductance and magnetic susceptibility etc. In this work, we reported studies and applications of high-Tc YBa2Cu3Oy SQUIDs. Two main techniques of depositing YBCO thin films are described; the characteristic of thin film and high-Tc SQUID are address...

متن کامل

Double Relaxation Oscillation SQUID Systems for Biomagnetic Multichannel Measurements

Multichannel superconducting quantum interference device (SQUID) systems based on double relaxation oscillation SQUIDs (DROS) were developed for measuring magnetocardiography (MCG) and magnetoencephalography (MEG) signals. Since DROS provides large fluxto-voltage transfer coefficients, about 10 times larger than the DC SQUIDs, direct readout of the SQUID output was possible using compact roomte...

متن کامل

Novel excitation coils for non-destructive evaluation of non-magnetic metallic structures by high-Tc dc SQUID

A non-destructive evaluation (NDE) system was set up in our laboratory. A high-Tc dc superconducting quantum interference device (dc SQUID) made from YBa2Cu3O7−δ thin film on a 24◦ bicrystal SrTiO3 substrate was adopted as the magnetic flux sensor. Novel excitation coils and a balance circuitry were proposed and employed for evaluation of multilayer aluminium structure with artificial slits in ...

متن کامل

Magnetocardiography in unshielded location in coronary artery disease detection using computerized classification of current density vectors maps

High sensetivity of magnetocardiography in patients with coronary artery disease and normal or unspecifically changed electrocardiogram. Budnik N., Fainzilberg L.(2000) :Possibilities of magnetocardiography in coronary artery disease detection in patients with normal or unspecifically changed ECG. Steinberg F.(2002): Computerized classification of patients with coronary artery disease but norma...

متن کامل

Optical Magnetometer Employing Adaptive Noise Cancellation for Unshielded Magnetocardiography

This paper demonstrates the concept of an optical magnetometer for magnetocardiography. The magnetometer employs a standard Least-Mean-Squares (LMS) algorithm for heart magnetic field measurement within unshielded environment. Experimental results show that the algorithm can extract a weak heart signal from a much-stronger magnetic noise and detect the P, QRS, and T heart features and completel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2003