Comparison of 3D and 2D Breast Density Estimation from Synthetic Ultrasound Tomography Images and Digital Mammograms of Anthropomorphic Software Breast Phantoms

نویسندگان

  • Predrag R. Bakic
  • Cuiping Li
  • Erik West
  • Mark Sak
  • Sara C. Gavenonis
  • Nebojsa Duric
  • Andrew D.A. Maidment
چکیده

Breast density descriptors were estimated from ultrasound tomography (UST) and digital mammogram (DM) images of 46 anthropomorphic software breast phantoms. Each phantom simulated a 450 ml or 700 ml breast with volumetric percent density (PD) values between 10% and 50%. The UST based volumetric breast density (VBD) estimates were calculated by thresholding the reconstructed UST images. Percent density (PD) values from DM images were estimated interactively by a clinical breast radiologist using Cumulus software. Such obtained UST VBD and Cumulus PD estimates were compared with the ground truth VBD values available from phantoms. The UST VBD values showed a high correlation with the ground truth, as evidenced by the Pearson correlation coefficient of r=0.93. The Cumulus PD values also showed a high correlation with the ground truth (r=0.84), as well as with the UST VBD values (r=0.78). The consistency in measuring the UST VBD and Cumulus PD values was analyzed using the standard error of the estimation by linear regression (σE). The σE value for Cumulus PD was 1.5 times higher compared to the UST VBD (6.54 vs. 4.21). The σE calculated from two repeated Cumulus estimation sessions (σE=4.66) was comparable with the UST. Potential sources of the observed errors in density measurement are the use of global thresholding and (for Cumulus) the human observer variability. This preliminary study of simulated phantom UST images showed promise for non-invasive estimation of breast density.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Power Spectrum Analysis of an Anthropomorphic Breast Phantom Compared to Patient Data in 2D Digital Mammography and Breast Tomosynthesis

Digital breast tomosynthesis (DBT) images of a novel anthropomorphic breast phantom (UPenn phantom) acquired on two breast tomosynthesis systems were analyzed in terms of their power spectra (PS). The β and κ power law coefficients were estimated from 2D planar, tomosynthesis projection images and reconstructed planes. These data were compared to the PS characteristics as retrieved from a group...

متن کامل

Development of a physical 3D anthropomorphic breast phantom.

PURPOSE Develop a technique to fabricate a 3D anthropomorphic breast phantom with known ground truth for image quality assessment of 2D and 3D breast x-ray imaging systems. METHODS The phantom design is based on an existing computer model that can generate breast voxel phantoms of varying composition, size, and shape. The physical phantom is produced in two steps. First, the portion of the vo...

متن کامل

3D Ultrasound Transmission Tomography Using Synthetic Aperture Focusing and Regularized Algebraic Reconstruction

Ultrasound transmission tomography is presented as an imaging modality for breast cancer diagnosis. A 3D reconstruction technique is proposed for estimation of soundspeed images for the Karlsruhe 3D ultrasound transmission tomograph. The problems of sparse spatial distribution of ultrasound transducers and of low signal-to-noise ratio are approached using synthetic aperture focusing. The image ...

متن کامل

Title: Simulation of 3D DLA masses in digital breast tomosynthesis

Digital breast tomosynthesis (DBT) is suggested to have superior performance compared to 2D mammography in terms of cancer visibility, especially in the case of dense breasts. However, the overall performance of tomosynthesis for screening applications, and the manner in which tomosynthesis should be optimally used for screening remains unclear. This motivates the development of software tools ...

متن کامل

Development and characterization of an anthropomorphic breast software phantom based upon region-growing algorithm.

PURPOSE We present a novel algorithm for computer simulation of breast anatomy for generation of anthropomorphic software breast phantoms. A realistic breast simulation is necessary for preclinical validation of volumetric imaging modalities. METHODS The anthropomorphic software breast phantom simulates the skin, regions of adipose and fibroglandular tissue, and the matrix of Cooper's ligamen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011