Establishment of optimal scan delay for multi-phase computed tomography using bolus-tracking technique in canine pancreas

نویسندگان

  • Soo-Young CHOI
  • Ho-Jung CHOI
  • Ki-Ja LEE
  • Young-Won LEE
چکیده

To establish a protocol for a multi-phase computed tomography (CT) of the canine pancreas using the bolus-tracking technique, dynamic scan and multi-phase CT were performed in six normal beagle dogs. The dynamic scan was performed for 60 sec at 1-sec intervals after the injection (4 ml/sec) of a contrast medium, and intervals from aortic enhancement appearance to aortic, pancreatic parenchymal and portal vein peaks were measured. The multi-phase CT with 3 phases was performed three times using a bolus-tracking technique. Scan delays were 0, 15 and 30 in first multi-phase scan; 5, 20 and 35 in second multi-phase scan; and 10, 25 and 40 sec in third multi-phase scan, respectively. Attenuation values and contrast enhancement pattern were analyzed from the aorta, pancreas and portal vein. The intervals from aortic enhancement appearance to aortic, pancreatic parenchymal and portal vein peaks were 3.8 ± 0.7, 8.7 ± 0.9 and 13.3 ± 1.5 sec, respectively. The maximum attenuation values of the aorta, pancreatic parenchyma and portal vein were present at scan sections with no scan delay, a 5-sec delay and a 10-sec delay, respectively. When a multi-phase CT of the canine pancreas is triggered at aortic enhancement appearance using a bolus-tracking technique, the recommended optimal delay times of the arterial and pancreatic parenchymal phases are no scan delay and 5 sec, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal scan delay depending on contrast material injection duration in abdominal multi-phase computed tomography of pancreas and liver in normal Beagle dogs

This study was conducted to establish the values for optimal fixed scan delays and diagnostic scan delays associated with the bolus-tracking technique using various contrast material injection durations in canine abdominal multi-phase computed tomography (CT). This study consisted of two experiments employing the crossover method. In experiment 1, three dynamic scans at the porta hepatis were p...

متن کامل

Optimization of scan delay for multi-phase computed tomography by using bolus tracking in normal canine kidney

This study was performed to optimize scan delays for canine kidney by using a bolus-tracking technique. In six beagle dogs, computed tomography (CT) of the kidney was performed three times in each dog with different scan delays after a bolus-tracking trigger of 100 Hounsfield units (HU) of aortic enhancement. Delays were 5, 20, 35, and 50 sec for the first scan, 10, 25, 40, and 55 sec for the s...

متن کامل

Automatic Bolus Tracking Versus Fixed Time-Delay Technique in Biphasic Multidetector Computed Tomography of the Abdomen

BACKGROUND Bolus tracking can individualize time delay for the start of scans in spiral computed tomography (CT). OBJECTIVES We compared automatic bolus tracking method with fixed time-delay technique in biphasic contrast enhancement during multidetector CT of abdomen. PATIENTS AND METHODS Adult patients referred for spiral CT of the abdomen were randomized into two groups; in group 1, the ...

متن کامل

Optimising the scan delay for arterial phase imaging of the liver using the bolus tracking technique

OBJECTIVE To optimize the delay time before the initiation of arterial phase scan in the detection of focal liver lesions in contrast enhanced 5 phase liver CT using the bolus tracking technique. PATIENTS AND METHODS Delay - the interval between threshold enhancement of 100 hounsfield unit (HU) in the abdominal aorta and commencement of the first arterial phase scan. Using a 16 slice CT scann...

متن کامل

The Use of Dynamic Computed Tomography to Measure Tissue Perfusion in Canine Tumours - Preliminary Results

Introduction: Dynamic computed tomography is used in human medicine to determine tumour perfusion, which has been shown to be useful for treatment planning and prognosis. Wash-in, peak and wash-out can be assessed using time-density curves (TDC). Five types of TDC’s have been determined and shown to have prognostic relevance in humans. The goal of our study was to establish this technique and d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 77  شماره 

صفحات  -

تاریخ انتشار 2015