Comparison of reliability of the eye optic disc cup and pallor areas in glaucoma diagnostics.
نویسندگان
چکیده
The aim of this paper is to compare the glaucoma diagnostic reliability of two optic disc parameters: the relative cup area size determined by the Heidelberg retina tomography and the relative pallor area size determined by the proposed algorithm of the optic disc image analysis. Both parameters were measured for 240 normal healthy eyes and 240 glaucomatous eyes. The diagnostic reliability of studied parameters were compared using normalized distance d of their statistical distributions obtained for normal healthy and glaucomatous eyes and by comparison of area sizes under their ROC (Receiver Operating Characteristic) curves. The normalized distances were 2.19 or 1.73 and the area sizes under ROC curves were 0.95 or 0.89 for relative cup or pallor area size. Both considered relative parameters are significantly influenced by the glaucoma and can be used in its diagnostics. The designed pallor analysis is less diagnostic reliable than the analysis of the cup.
منابع مشابه
A Method of Segmentation For Glaucoma Screening Using Superpixel Classification
ABSTRACT: Glaucoma is a chronic eye disease that leads to vision loss. Detecting glaucoma in time is critical. The symptoms of the glaucoma disease occur when it is in advanced stage. Hence, glaucoma is called the silent thief of sight. Detecting the disease in time is very important. In this project, an optic disc and optic cup segmentation is used to identify the glaucoma disease in time. In ...
متن کاملEffects of three months treatment with sertraline on intraocular pressure and cup-to-disc ratio in patients with anxiety disorders/mixed anxiety and depressive disorder/major depressive disorder and without underlying eye disease
Exposure to selective serotonin reuptake inhibitors causes pupillary dilator muscle stimulation, active mydriasis, rapid rise in the level of the intraocular pressure (IOP), damage to the optic nerve at the back of the eye, and ultimately leads to acute angle closure glaucoma. The aim of this study was to assess the effects of sertraline on the levels of IOP and cup-to-disc ratio (CDR) in patie...
متن کاملOptic disc topography in Malay patients with normal-tension glaucoma and primary open-angle glaucoma
BACKGROUND There are limited data concerning the optic disc topography in normal-tension glaucoma (NTG) and primary open-angle glaucoma (POAG) patients living in Southeast Asian countries. This study aims to compare optic disc parameters in patients with NTG and POAG in Malaysia and to discuss the results in comparison with studies of NTG and POAG in other Asian countries. METHODS This prospe...
متن کاملThe Suspicious Nerve – Guilty Until Proven Innocent Introduction/Overview
1) Evaluation of the Optic Nerve requires descriptive quantitative and qualitative intrapapillary and parapapillary regions of the optic nerve head and the retinal nerve fiber layer (RNFL)variables including: a. Size and shape of the optic disc b. Size, shape and pallor of the neuroretinal rim c. Configuration and depth of the optic cup d. Cup-disc diameter ratio and cup-disc area ratio e. Posi...
متن کاملEvaluation of Retinal Optic Disc Segmentation in Patients with Glaucoma and Comparison with Other Methods of Medical Image Processing
Introduction: Glaucoma is the most common cause of blindness in some countries. In the meantime, the field of retinal image processing has been proposed in order to provide automatic systems for disease diagnosis. Among the methods of medical image processing, image segmentation is a process of identification and change in the display of an image. The objective of this study was to use t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Collegium antropologicum
دوره 37 Suppl 1 شماره
صفحات -
تاریخ انتشار 2013