T2-prepared SSFP Improves Diagnostic Confidence in Edema Imaging in Acute Myocardial Infarction Compared with Turbo-SpinEcho

نویسندگان

  • P. Kellman
  • A. H. Aletras
  • C. Mancini
  • E. R. McVeigh
  • A. E. Arai
چکیده

Introduction T2-weighted MR imaging of edema in acute myocardial infarction (MI) provides a means of differentiating acute and chronic MI and for assessing the area-at-risk of infarction. Standard T2-weighted imaging of edema uses a turbo-SpinEcho (TSE) readout with dark-blood preparation. Dark-blood TSE methods are subject to artifacts such as posterior wall signal loss due to cardiac motion and bright sub-endocardial rims due to stagnant blood which pose a significant limitation to clinical use. Thus clinical application of T2-weighted CMR is hindered primarily by artifacts. Single-shot imaging with T2-prepared SSFP (true-FISP) readout provides an alternative to dark-blood TSE and may be conducted during free-breathing. This is desirable where patients cannot tolerate breath-holding. We hypothesized that T2-prepared SSFP (1) improves signal homogeneity in normal hearts and (2) increases diagnostic accuracy in characterizing MI-related edema in patients relative to dark-blood TSE. Methods The proposed approach uses a T2-prepared single-shot true-FISP readout with parallel imaging. Repeated images were acquired, corrected for respiratory motion, and averaged to enhance SNR. The T2-prepared FISP sequence was compared with dark-blood prepared TSE in both normal volunteers and in 31 patients with MI, 22 acute (within 8 days of acute event) and 9 chronic (> 1 year). Images were acquired on a Siemens Espree 1.5T widebore scanner. In-plane resolution was typically 1.9x2.5 mm with 6mm slice-thickness. ECG triggering used 2 R-R intervals between readouts. TSE images used a double inversion-recovery dark-blood prep with 300% slice-thickness for selective component, BW=449Hz/pixel, echo-train-length=25, TE=64 ms. Single-shot T2-prepared FISP images used a BW=977Hz/pixel, TE/TR=1.6/3.2 ms, flip angle=90°, T2-prep TE=60ms, 8 repetitions. Parallel imaging (rate=2) was used to obtain the full resolution in a single heartbeat. Delayed enhancement imaging was performed using a segmented turboFLASH sequence. Results In normal volunteers (n=8) where uniform T2-weighted signal intensity is expected, the loss in signal intensity of the posterior wall of the LV (midventricular SAX slice) compared to the septal wall was 22.6±13.7% (mean±SD) using TSE, and 0.6%±4.2% using T2-prepared FISP. Both methods had surface coil intensity correction, and TSE images used timing optimized for minimal cardiac motion. A signal loss of 23% would represent a large fraction of the expected difference in signal intensity between acute MI and normal myocardium. T2-weighted imaging in patients was performed with both methods prior to contrast administration and delayed enhancement imaging of viable myocardium. While the SNR of the edema region for both methods was quite good (Fig 1), the T2-weighted images using TSE were non-diagnostic in 3-of-31 images, while 6 additional cases (Fig 2) rated diagnostic quality but the incorrect diagnosis (incorrect coronary territory). In all 31 cases the T2-prepared FISP was rated diagnostic quality and yielded the correct diagnosis (Fig 3). Discussion The proposed bright blood T2-prepared SSFP approach overcomes artifacts such as posterior wall signal loss due to cardiac motion and bright subendocardial rims due to stagnant blood (Fig 4) which pose a significant limitation to more widely used dark-blood T2-weighted methods. The TSE method was sensitive to RR variation and image quality suffered at higher heart rates, whereas the single shot T2-prepared FISP approach was robust to such variation and enabled non-breathhold imaging. T2-prepared FISP may be used clinically for reliable T2-weighted imaging in acute MI. References [1] Abdel-Aty H, et al. Circulation. 2004;109:2411-2416. [3] Keegan, J, et al. JMRI 2006;24:563-570. [2] Aletras AH, et al. Circulation. 2006;113(15):1865-1870. [4] Pennell D. Circulation. 2006;113(15):1821-1823.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

T2-prepared SSFP improves diagnostic confidence in edema imaging in acute myocardial infarction compared to turbo spin echo.

T2-weighted MRI of edema in acute myocardial infarction (MI) provides a means of differentiating acute and chronic MI, and assessing the area at risk of infarction. Conventional T2-weighted imaging of edema uses a turbo spin-echo (TSE) readout with dark-blood preparation. Clinical applications of dark-blood TSE methods can be limited by artifacts such as posterior wall signal loss due to throug...

متن کامل

ACUT2E TSE-SSFP: a hybrid method for T2-weighted imaging of edema in the heart.

ACUT(2)E TSE-SSFP is a hybrid between steady state free precession (SSFP) and turbo spin echo (TSE) for bright-blood T2-weighted imaging with signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) similar to dark-blood TSE. TSE-SSFP uses a segmented SSFP readout during diastole with 180 degrees pulses following a 90 degrees preparation. The 180 degrees refocusing pulses make TSE-SSFP sim...

متن کامل

SSFP cine images early post-gadolinium improve detection of myocardial oedema in acute myocardial infarction compared to T2-weighted dark blood turbo spin echo images

Background Demonstration of myocardial oedema following MI allows differentiation of acute and chronic MI, and assessment of the area at risk of infarction. T2-weighted dark blood TSE imaging for oedema is technically demanding and prone to artefacts. Our protocol for patients with acute MI include standard oedema imaging sequences and more recently T2 prepared single shot SSFP sequences, follo...

متن کامل

A Comparative Study of Different CMR Methods for Detecting Myocardial Edema Associated with Acute Myocardial Infarction

Introduction: A number of CMR imaging approaches have been proposed for detecting myocardial edema accompanying acute myocardial infarctions (AMI). T1 [1] and T2 [2] maps, T2-prepared SSFP [3] and cine SSFP (bSSFP) [4,5] are potential alternatives to the most commonly employed T2-weighted STIR (T2-STIR) [6] imaging. However, the relative sensitivities of the various approaches in relation to th...

متن کامل

Clinical utility of cardiac magnetic resonance T2 mapping for acute myocardial edema

Background Edema is a generic tissue response to acute myocardial injury and, therefore; a potential marker of impending tissue damage. Currently in clinical use, T2 weighted imaging provides a qualitative technique in assessing myocardial edema. We hypothesize that quantitative T2 mapping in patients with suspected cases of myocarditis, myocardial infarction (AMI), and cardiac transplant rejec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006