The deposition mode ice nucleation efficiency of various dust aerosols was investigated at cirrus cloud temperatures between 196 and 223 K using the aerosol and cloud chamber facility AIDA (Aerosol Interaction and Dynamics in the Atmosphere). Arizona test dust (ATD) as a reference material and two dust samples from the Takla Makan desert in Asia (AD1) and the Sahara (SD2) were used for the experiments at simulated cloud conditions. The dust particle sizes were almost lognormally distributed with mode diameters between 0.3 and 0.5 μm and geometric standard deviations between 1.6 and 1.9. Deposition ice nucleation was most efficient on ATD particles with ice-active particle fractions of about 0.6 and 0.8 at an ice saturation ratio Si<1.15 and temperatures of 223 and 209 K, respectively. No significant change of the ice nucleation efficiency was found in up to three subsequent cycles of ice activation and evaporation with the same ATD aerosol. This indicates that the phenomenon of preactivation does not apply to ATD particles. The desert dust samples SD2 and AD1 showed a significantly lower fraction of active deposition nuclei, about 0.25 at 223 K and Si<1.35. For all samples the ice activated aerosol fraction could be approximated by an exponential equation as function of Si . This indicates that deposition ice nucleation on mineral particles may not be treated in the same stochastic sense as homogeneous freezing. The suggested formulation of ice activation spectra may be used to calculate the formation rate of ice crystals in models, if the number concentration of dust particles is known. More experimental work is needed to quantify the variability of the Correspondence to: O. Möhler ([email protected]) ice activation spectra as function of the temperature and dust particle properties.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ice nucleation on mineral dust

Efficiency of the deposition mode ice nucleation on mineral dust particles O. Möhler, P. R. Field, P. Connolly, S. Benz, H. Saathoff, M. Schnaiter, R. Wagner, R. Cotton, M. Krämer, A. Mangold, and A. J. Heymsfield Forschungszentrum Karlsruhe, Institute for Meteorology and Climate Research (IMK-AAF), Germany Met Office, OBR (Observations Based Research), UK University of Manchester, School of Ea...

متن کامل

Influence of particle size on the ice nucleating ability of mineral dusts

The recently developed Zurich Ice Nucleation Chamber (ZINC) was used to explore ice nucleation of size-selected mineral dust particles at temperatures between −20C and −55C. Four different mineral dust species have been tested: montmorillonite, kaolinite, illite and Arizona test dust (ATD). The selected particle diameters are 100 nm, 200 nm, 400 nm and 800 nm. Relative humidities with respect t...

متن کامل

Laboratory investigations of the impact of mineral dust aerosol on cold cloud formation

Dust particles represent a dominant source of particulate matter (by mass) to the atmosphere, and their emission from some source regions has been shown to be transported on regional and hemispherical scales. Dust particles’ potential to interact with water vapor in the atmosphere can lead to important radiative impacts on the climate system, both direct and indirect. We have investigated this ...

متن کامل

High variability of the heterogeneous ice nucleation potential of oxalic acid dihydrate and sodium oxalate

The heterogeneous ice nucleation potential of airborne oxalic acid dihydrate and sodium oxalate particles in the deposition and condensation mode has been investigated by controlled expansion cooling cycles in the AIDA aerosol and cloud chamber of the Karlsruhe Institute of Technology at temperatures between 244 and 228 K. Previous laboratory studies have highlighted the particular role of oxal...

متن کامل

Experimental investigation of ice nucleation by different types of aerosols in the aerosol chamber AIDA: implications to microphysics of cirrus clouds

The aerosol chamber AIDA was used as a moderate expansion cloud chamber with cooling rates at the onset of ice nucleation between –1.3 and –3.0 K min−1 to investigate the nucleation and growth of ice crystals in sulphuric acid, ammonium sulphate, and mineral dust aerosols at temperatures between 196 and 224 K. Supercooled sulphuric acid droplets with mean diameters of about 0.2 to 0.3 μm nuclea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006