Reliability of noncontact pachymetry after laser in situ keratomileusis.
نویسندگان
چکیده
PURPOSE To assess the repeatability and reproducibility of central corneal thickness (CCT) measurements obtained by combined scanning-slit/Placido-disc topography (Orbscan II; Bausch & Lomb, Rochester, NY) after laser in situ keratomileusis (LASIK) and to compare the results with another noncontact method, specular microscopy (SP-2000P; Topcon, Tokyo, Japan). METHODS To analyze intrasession repeatability, one examiner measured 22 postmyopic LASIK eyes 10 times successively in the shortest time possible, using both devices randomly. To study intersession reproducibility, the same operator obtained measurements from another 50 eyes with stable refraction in two consecutive visits at the same time of the day between 6 and 9 months after myopic LASIK. Any association between residual stromal bed thickness and measurement variability was recorded and evaluated. RESULTS For intrasession repeatability, Orbscan II and Topcon SP-2000P CCT measurements showed a repeatability of 20.2 (4.3%) and 12.8 (2.6%) microm, respectively. Both devices yielded excellent intraclass correlation coefficients (ICC; 0.98 and 0.99, respectively). For intersession reproducibility, no difference in CCT measurements was found. The coefficient of intersession reproducibility were 6.7% (29.5 microm) for Orbscan II and 4.3% (19.5 microm) for Topcon SP-2000P CCT measurements. The ICCs (0.95 and 0.96, respectively) indicated good intersession reliability. Repeatability and reproducibility with both devices were unrelated to stromal bed thickness. CONCLUSIONS Both noncontact pachymeters provide repeatable CCT measurements in transparent postmyopic LASIK corneas after the early postoperative period. Intersession variations in CCT of more than 29 microm with the Orbscan II and 19 microm with the Topcon SP-2000P may reflect true corneal change. These estimates should help investigators and clinicians differentiate actual CCT modification from measurement variability.
منابع مشابه
Comparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusis.
AIMS To compare central corneal thickness measurements of three pachymetry devices in eyes after laser in situ keratomileusis (LASIK). METHODS Central corneal thickness was measured in 203 eyes after myopic LASIK. Orbscan II scanning slit topography (Bausch & Lomb), SP-2000P non-contact specular microscopy (Topcon), and ultrasonic pachymetry (Tomey) were used in this sequence. RESULTS Three...
متن کاملSCIENTIFIC REPORT Comparison of corneal thickness measurements using Orbscan II, non-contact specular microscopy, and ultrasonic pachymetry in eyes after laser in situ keratomileusis
Aims: To compare central corneal thickness measurements of three pachymetry devices in eyes after laser in situ keratomileusis (LASIK). Methods: Central corneal thickness was measured in 203 eyes after myopic LASIK. Orbscan II scanning slit topography (Bausch & Lomb), SP-2000P non-contact specular microscopy (Topcon), and ultrasonic pachymetry (Tomey) were used in this sequence. Results: Three ...
متن کاملComparison of Intraocular Pressure before and after Laser In Situ Keratomileusis Refractive Surgery Measured with Perkins Tonometry, Noncontact Tonometry, and Transpalpebral Tonometry
Purpose. To compare the intraocular pressure (IOP) before and after Laser In Situ Keratomileusis (LASIK), measured by Diaton, Perkins, and noncontact air pulse tonometers. Methods. Fifty-seven patients with a mean age of 34.88 were scheduled for myopia LASIK treatment. Spherical equivalent refraction (SER), corneal curvature (K), and central corneal thickness (CCT) and superior corneal thicknes...
متن کاملAccuracy of Alcon WaveLight® EX500 optical pachymetry during LASIK
PURPOSE To study the accuracy and reliability of optical pachymetry using the Alcon WaveLight EX500 during laser-assisted in situ keratomileusis (LASIK). MATERIALS AND METHODS This was a retrospective chart review of 90 eyes from 45 patients who had undergone LASIK (mean age 35.2±8.2 years; 19 males, 26 females). The WaveLight FS200 femtosecond laser was programmed to cut LASIK flaps at a des...
متن کاملCentral corneal thickness measurements using Orbscan II, Visante, ultrasound, and Pentacam pachymetry after laser in situ keratomileusis for myopia.
PURPOSE To compare corneal pachymetry assessment using 4 measurement methods in eyes after laser in situ keratomileusis (LASIK) for myopia. SETTING Department of Ophthalmology & Visual Sciences, The Chinese University of Hong Kong, Hong Kong Eye Hospital, Hong Kong SAR. METHODS Fifty-two consecutive patients (103 eyes) who had LASIK for the correction of myopia had Orbscan II (Bausch & Lomb...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 50 9 شماره
صفحات -
تاریخ انتشار 2009