Supporting Information Delayed voltammetric with respect to amperometric electrochemical detection of concentration changes in microchannels

نویسندگان

  • Raphaël Trouillon
  • Martin A. M. Gijs
چکیده

Obtaining the peak current ip from raw CV data The raw CV data obtained during the experiments featured two characteristics, which could potentially complicate the data analysis. First, because of the relatively high scan rate (10 V s) used for these experiments, the background current was quite important and could potentially hinder the determination of the concentration profiles from the voltammetric data. Additionally, minute variations in the first voltage sweeps of the acquisition, due to electrode discharge or stabilization, could introduce further inaccuracies. For these reasons, CV measurements were performed in the background buffer (PBS) and were substracted from the raw data (Figure S1). This background substraction method is routinely used for the processing of fast-scan CV data. From the resulting signal, the peak currents ip could be identified, and the time variations of these currents was analyzed and plotted on graphs, such as the ones presented in the main text.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Delayed voltammetric with respect to amperometric electrochemical detection of concentration changes in microchannels.

The time response of an electrode incorporated into a fluidic channel to variations in analyte concentration of the outer-sphere redox probe ferrocenemethanol was investigated both for amperometry (AMP) and cyclic voltammetry (CV). The experimental data show that the temporal resolution of CV is not as good as that of AMP, as CV cannot properly detect fast concentration transients. The delayed ...

متن کامل

Voltammetric Electrochemical Detection of Concentration Changes in a Microfluidic Chip Is Delayed in Comparison to Amperometry

The time responses of two electrochemical methods, amperometry (AMP) and cyclic voltammetry (CV), used in a microchannel to detect the concentration variations of an outer-sphere redox species were compared. Overall, our results show that the temporal resolution of AMP is superior to the one of CV. As no secondary reaction (formation of chemical bounds, adsorption, etc.) can hinder the detectio...

متن کامل

Determination of selected phenolic acids in beer extract by liquid chromatography with voltammetric-amperometric detection.

A voltammetric-amperometric detector for liquid chromatography based on a dual electrode electrochem-ical cell has been developed. This detector enables voltammograms to be obtained without the charging current problems inherent in single electrode voltammetric detectors. The detector is operated by scanning the potential of the upstream (voltammetric) electrode and detecting the electrolysis p...

متن کامل

An Electrochemical Sensor Based on Novel Ion Imprinted Polymeric Nanoparticles for Selective Detection of Lead Ions

In this study, the novel surface ion-imprinted polymer (IIP) particles were prepared and applied as a electrode modifier in stripping voltammetric detection of lead(II) ion. A carbon paste electrode (CPE) modified with IIP nanoparticles and multi-walled carbon nanotubes (MWCNTs) was used for accumulation of toxic lead ions. Various factors that govern on electrochemical signals including carbon...

متن کامل

A Simple and an Effective Catalyst for Determination of Cefixime in Real Samples Using of Modified Carbon Paste Electrode with Cobalt Impregnated Zeolite

Carbon paste electrode modified with cobalt impregnated zeolite was prepared by mixing of cobalt_zeolite (Co_Z) and graphite powder with different percent. The electrochemical oxidation of cefixime at such electrodes was investigated using the cyclic voltammetric and amperometric techniques. It is not electrochemically active towards cefixime oxidation in 0.1 M phosphate buffer solution (pH=7) ...