Development of a certified reference material (NMIJ CRM 7531-a) for the determination of trace cadmium and other elements in brown rice flour.
نویسندگان
چکیده
A certified reference material (CRM) for trace cadmium and other elements in brown rice flour was developed at the National Metrology Institute of Japan (NMIJ). The CRM was provided as a dry powder after drying and frozen pulverization of fresh brown rice obtained from a Japanese domestic market. Characterization of the property value for each element was carried out exclusively by NMIJ with at least two independent analytical methods, including inductively coupled plasma mass spectrometry (ICP-MS), ICP high-resolution mass spectrometry, isotope-dilution ICP-MS, ICP optical emission spectrometry, and graphite-furnace atomic-absorption spectrometry. Property values were provided for six elements (Mn, Fe, Cu, Zn, As, and Cd). The concentration range of the property values was from 0.280 mg kg(-1) of As to 31.8 mg kg(-1) of Zn. The combined relative standard uncertainties of the property values were estimated by considering the uncertainties of the homogeneity, characterization, difference among analytical methods, dry-mass correction factor, and calibration standard. The range of the relative combined standard uncertainties was from 1.1% of Zn to 1.6% of As.
منابع مشابه
Development and validation of routine analysis methods for the determination of essential, nonessential, and toxic minor and trace elements in cereal and cereal flour samples by inductively coupled plasma-atomic emission spectrometry.
Various digestion procedures were carefully investigated and accurately evaluated with respect to their effect on the analysis of cereals and cereal flours. Multielement methods were selected and well developed for the determination of essential (Cr, Cu, Fe, Mg, Mn, and Zn), nonessential (Ag, Al, Ba, Bi, In, and Ga), and toxic (Cd and Pb) minor and trace elements by inductively coupled plasma-a...
متن کاملFlotation/magnetic stirring-assisted liquid-liquid microextraction combined with flame atomic absorption spectrometry for the preconcentration and determination of cadmium (II) after optimization using experimental design
Arapid, highly sensitive and efficient flotation/magnetic stirring-assisted liquid-liquid microextraction combined with flame atomic absorption spectrometry has been proposed for the preconcentration and quantitative analysis of trace amounts of cadmium (II) in the presence of sodium diethyldithiocarbamateas complexingagent. Parameters including sample pH, concentration of the complexingagent, ...
متن کاملExposure Assessment of the Tehran Population (Iran) to Zearalenone Mycotoxin
Zearalenone (ZEA) mycotoxin is a potent estrogenic metabolite. It is the primary toxin causing infertility, abortion or other breeding problems. A HPLC method was validated for ZEA in foods using a monolithic column with sample clean-up on an immunoaffinity column. A certified reference material (CRM) from FAPAS (UK) was analyzed. A survey of ZEA was performed on the 72 samples of rice, bread, ...
متن کاملExposure Assessment of the Tehran Population (Iran) to Zearalenone Mycotoxin
Zearalenone (ZEA) mycotoxin is a potent estrogenic metabolite. It is the primary toxin causing infertility, abortion or other breeding problems. A HPLC method was validated for ZEA in foods using a monolithic column with sample clean-up on an immunoaffinity column. A certified reference material (CRM) from FAPAS (UK) was analyzed. A survey of ZEA was performed on the 72 samples of rice, bread, ...
متن کاملPrecise determination of Cr and Co in certified reference material of silicon nitride by neutron activation analysis using internal standardization.
Neutron activation analysis with an internal standard correction was applied to the determination of Cr and Co in a ceramics certified reference material (NMIJ CRM 8004-a silicon nitride powder). Cesium was used as an internal standard to compensate for any inhomogeneity of the neutron flux through an irradiation capsule and to improve the repeatability of gamma-ray measurements. It was found t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 28 12 شماره
صفحات -
تاریخ انتشار 2012