Molar pregnancy with false negative urine hCG: the hook effect.

نویسندگان

  • Y P Pang
  • H Rajesh
  • L K Tan
چکیده

Urine pregnancy tests are widely used in emergency departments as the first screening test for patients of reproductive age presenting with gynaecological problems in order to rule out pregnancy. Conditions such as complete molar pregnancy, which produces large amounts of beta human chorionic gonadotropin (beta-hCG), may cause a false negative result due to an oversaturation of the assay system, known as the "hook effect". We report a case where the exclusion of pregnancy by urine testing led to the initial misdiagnosis of a molar pregnancy as a degenerative fibroid. Physicians need to be reminded of the possibility of false negative results with this commonly used test. Negative or inconclusive results in patients with a high suspicion of pregnancy should be further evaluated by serum quantification of beta-hCG and appropriate sample dilution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Molar Pregnancy with False Negative β-hCG Urine in the Emergency Department

This case describes an atypical presentation of molar pregnancy in an emergency department patient with abdominal pain and vaginal bleeding. The patient demonstrated clinical features of hydatidiform mole, including acute discharge of a large, grape-like vesicular mass, despite multiple negative urine pregnancy tests. These false-negative qualitative human chorionic gonadotropin assays were lik...

متن کامل

The “hook effect” causing a negative pregnancy test in a patient with an advanced molar pregnancy

•At high hCG levels in molar pregnancies, a "hook effect" can cause an artificially negative value.•Delay in diagnosis of a molar pregnancy due to the "hook effect" can lead to severe complications.•Suspicion of a molar pregnancy should be communicated so a diluted sample is used to quantify hCG.

متن کامل

Qualitative point-of-care human chorionic gonadotropin testing: can we defuse this ticking time bomb?

Qualitative point-of-care (POC) human chorionic gonadotropin (hCG) testing is routinely performed on urine samples obtained in the Emergency Department (ED) or before surgery to rule out pregnancy and prevent fetal injury or death. Because potentially harmful treatments are allowed to proceed on the basis of a negative hCG test result, falsenegative results can have disastrous consequences. We ...

متن کامل

Screening method to evaluate point-of-care human chorionic gonadotropin (hCG) devices for susceptibility to the hook effect by hCG β core fragment: evaluation of 11 devices.

BACKGROUND The predominant hCG variant in urine, hCG β core fragment (hCGβcf), has been demonstrated to cause false-negative results in qualitative point-of-care (POC) hCG devices. This is a major concern for healthcare professionals using POC pregnancy tests. We developed a screening method to evaluate qualitative POC hCG devices for their susceptibility to inhibition by hCGβcf. Using this met...

متن کامل

Cost benefit analysis of same day pregnancy tests in elective orthopaedic surgery.

UNLABELLED We reviewed the results of 4,723 day of surgery pregnancy tests performed at two of our institution's locations, our ambulatory surgery center and our acute orthopaedics hospital over a 23 month time period. All patients were scheduled for elective orthopaedic surgery. There were seven positive results (0.15%) and one false negative result (0.02%). The cost per positive result for bo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Singapore medical journal

دوره 51 3  شماره 

صفحات  -

تاریخ انتشار 2010