Quality assurance in stereotactic radiosurgery/radiotherapy according to DIN 6875-1.

نویسندگان

  • A Mack
  • G Mack
  • S Scheib
  • H Czempiel
  • H J Kreiner
  • N J Lomax
  • S Gianolini
  • M Rieker
  • D Weltz
  • R Wolff
  • A Muacevic
  • B Wowra
  • H D Böttcher
  • V Seifert
چکیده

The new DIN ('Deutsche Industrie-Norm') 6875-1, which is currently being finalised, deals with quality assurance (QA) criteria and tests methods for linear accelerator and Gamma Knife stereotactic radiosurgery/radiotherapy including treatment planning, stereotactic frame and stereotactic imaging and a system test to check the whole chain of uncertainties. Our existing QA program, based on dedicated phantoms and test procedures, has been refined to fulfill the demands of this new DIN. The radiological and mechanical isocentre corresponded within 0.2 mm and the measured 50% isodose lines were in agreement with the calculated ones within less than 0.5 mm. The measured absorbed dose was within 3%. The resultant output factors measured for the 14-, 8- and 4-mm collimator helmet were 0.9870 +/- 0.0086, 0.9578 +/- 0.0057 and 0.8741 +/- 0.0202, respectively. For 170 consecutive tests, the mean geometrical accuracy was 0.48 +/- 0.23 mm. Besides QA phantoms and analysis software developed in-house, the use of commercially available tools facilitated the QA according to the DIN 6875-1 with which our results complied.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Isocenter verification for linac‐based stereotactic radiation therapy: review of principles and techniques

There have been several manual, semi-automatic and fully-automatic methods proposed for verification of the position of mechanical isocenter as part of comprehensive quality assurance programs required for linear accelerator-based stereotactic radiosurgery/radiotherapy (SRS/SRT) treatments. In this paper, a systematic review has been carried out to discuss the present methods for isocenter veri...

متن کامل

Stereotactic Radiosurgery/Radiotherapy: A Historical Review

"Stereotactic" is an exact radiotherapy treatment modality which implements invasive and non-invasive facilities for improving precise dose delivery. Stereotactic refers to three-dimensional localization of a specific point in space by a unique set of coordinates that relate to a fixed external reference frame. An accurate delivery of radiation is attainable using these techniques with high pre...

متن کامل

Recommendations for implementing stereotactic radiotherapy in peripheral stage IA non-small cell lung cancer: report from the Quality Assurance Working Party of the randomised phase III ROSEL study

BACKGROUND A phase III multi-centre randomised trial (ROSEL) has been initiated to establish the role of stereotactic radiotherapy in patients with operable stage IA lung cancer. Due to rapid changes in radiotherapy technology and evolving techniques for image-guided delivery, guidelines had to be developed in order to ensure uniformity in implementation of stereotactic radiotherapy in this mul...

متن کامل

Precise film dosimetry for stereotactic radiosurgery and stereotactic body radiotherapy quality assurance using Gafchromic™ EBT3 films

PURPOSE The purpose of this study is to evaluate the dosimetric uncertainty associated with Gafchromic™ (EBT3) films and establish a practical and efficient film dosimetry protocol for Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiotherapy (SBRT). METHOD AND MATERIALS EBT3 films were irradiated at each of seven different dose levels between 1 and 15 Gy with open fields and standar...

متن کامل

Challenges for Quality Assurance of Target Volume Delineation in Clinical Trials

In recent years, new radiotherapy techniques have emerged that aim to improve treatment outcome and reduce toxicity. The standard method of evaluating such techniques is to conduct large scale multicenter clinical trials, often across continents. A major challenge for such trials is quality assurance to ensure consistency of treatment across all participating centers. Analyses from previous stu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stereotactic and functional neurosurgery

دوره 82 5-6  شماره 

صفحات  -

تاریخ انتشار 2004