The width of the uterine cavity is narrower in patients with an embedded intrauterine device (IUD) compared to a normally positioned IUD.
نویسندگان
چکیده
OBJECTIVE The purpose of this study was to determine whether women with intrauterine devices (IUDs) embedded in the myometrium or cervix have a narrower fundal transverse endometrial diameter as seen on 3-dimensional (3D) sonography compared to women whose IUDs are in a normal location. METHODS A sonographer blinded to the study hypothesis retrospectively evaluated the 3D images and reconstructed coronal views of the uterine cavity in 172 consecutive women who had an IUD in the uterus. The width of the endometrial cavity at the fundus of the uterus was measured transversely on the rendered coronal sonogram using the calipers on a picture archiving and communications system. The measurements obtained from women who had nonembedded IUDs were compared to those with embedded IUDs. RESULTS Measurement of the width of the endometrial cavity at the fundus was successfully performed in 132 patients with nonembedded IUDs and 29 with embedded IUDs. The mean ± SD values of the fundal uterine cavity for the nonembedded and embedded IUDs were 32 ± 1.0 and 25 ± 0.8 mm, [corrected] respectively (P = .0003). CONCLUSIONS Patients with embedded IUDs have a smaller fundal endometrial cavity diameter compared to those with normally placed IUDs as documented using 3D rendering of the uterus. Whether preprocedural 3D sonography for women who are IUD candidates would be useful deserves further study.
منابع مشابه
The Role of Three Dimensional Transvaginal Ultrasound in Detection of Intrauterine Device Displacement in Post Caesarean Section: A Case Report
Intrauterine Devices (IUDs) are used as an efficient and inexpensive method of contracep¬tion. Contraceptive efficacy depends on the intrauterine location of IUD and intrauterine displacement of the IUD leads to decreased contraceptive efficacy. Expulsion of IUD and its penetration into myometrium is one of the complications of IUD. In cases where IUDs are not detected by ultrasound method, in ...
متن کاملAsymptomatic small bowel serosa translocation of intra uterine device, A case report
Introduction: One of the serious complications of intra uterine device (IUD) is uterine perforation and translocation of it to abdominal organs. Translocation is usually accompanied with abdominal or pelvic pain and absence of string in vaginal examination. Therefore, it was decided to report an asymptomatic case of translocation of IUD to small bowel serosa with presence of string in vaginal e...
متن کاملThree-dimensional ultrasound detection of abnormally located intrauterine contraceptive devices which are a source of pelvic pain and abnormal bleeding.
OBJECTIVE To determine whether intrauterine contraceptive devices (IUDs) that are located abnormally within the myometrium or cervix cause a higher incidence of pelvic pain and abnormal bleeding compared with normally positioned devices. METHODS Over a period of 9 months, all patients with an IUD presenting at our unit for two-dimensional pelvic ultrasound underwent a three-dimensional (3D) v...
متن کاملLippes Loop intrauterine device left in the uterus for 50 years: case report
BACKGROUND The first Lippes Loop intrauterine device (IUD) was introduced in 1962. It was a plastic double "S" loop, a trapezoid shaped IUD that closely fit around the contours of the uterine cavity, reducing the incidence of expulsion. This IUD was commonly used from the 1960's to the 1980's. Some authors state that the IUD can be left in the uterine cavity for an indefinite amount of time. Pr...
متن کاملEmbedded stainless steel ring intrauterine device.
The stainless steel ring intrauterine device (IUD) (Figure 1A) is widely used in China. Very often this type of IUD can be removed in the outpatient clinic by using an IUD removal hook. A 32-year-old Chinese woman was referred for removal of an IUD that had been inserted 7 years previously in China. With the use of an IUD removal hook, only part of the device, which appeared to be a stainless s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine
دوره 29 10 شماره
صفحات -
تاریخ انتشار 2010