Corneal aberrometric and refractive performance of 2 intrastromal corneal ring segment models in early and moderate ectatic disease.

نویسندگان

  • David P Piñero
  • Jorge L Alió
  • Bassam El Kady
  • Inmaculada Pascual
چکیده

PURPOSE To evaluate and compare visual, refractive, and corneal aberrometric outcomes after implantation of 2 types of intrastromal corneal ring segments (ICRS) in eyes with early to moderate ectatic disease. SETTINGS Vissum Corporation-Instituto Oftalmológico de Alicante, Alicante, Spain. METHODS This retrospective analysis comprised consecutive eyes with grade I or grade II corneal ectasia (keratoconus, pellucid marginal degeneration, ectasia after laser in situ keratomileusis) that had Intacs (Group I) or KeraRings (Group K) ICRS implantation using femtosecond technology. Visual, refractive, and corneal aberrometric outcomes were analyzed and compared between groups over a 6-month follow-up. RESULTS Group I had 17 eyes and Group K, 20 eyes. One month postoperatively, there was a statistically significant reduction in sphere in both groups (P<or=.02). At 6 months, there was a statistically significant reduction in manifest cylinder in Group K that was consistent with the significant reduction in corneal astigmatic aberration (both P = .04). The uncorrected distance visual acuity increased significantly in Group K (P = .04) but not in Group I; 41.18% of eyes in Group I and 52.94% in Group K gained 1 or more lines of corrected distance visual acuity. Both groups had significant corneal flattening (P<or=.02). At 1 month, the mean primary spherical aberration was -0.17 microm +/- 0.52 (SD) in Group I and 0.40 +/- 0.35 microm in Group K; the difference was statistically significant (P<.01). CONCLUSION Astigmatism correction in early to moderate ectatic corneas was more limited with the Intacs ICRS, which induced negative primary spherical aberration in the initial postoperative period. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Modeling the intracorneal ring segment effect in keratoconus using refractive, keratometric, and corneal aberrometric data.

PURPOSE To characterize the refractive, keratometric, and corneal aberrometric effect of a specific type of intracorneal ring segment (ICRS) as a function of its thickness and the preoperative conditions of the cornea. METHODS A total of 72 consecutive keratoconic eyes of 57 patients ranging in age from 15 to 68 years were retrospectively analyzed and included in the study. All cases had a di...

متن کامل

Corneal Hydrops Secondary to Intrastromal Corneal Ring Intrusion into the Anterior Chamber 7 Years after Implantation: A Case Report

INTRODUCTION This report describes the first known case of late-onset intrusion of an intrastromal ring segment into the anterior chamber due to posterior migration of a ring segment. To our knowledge, intrastromal ring segment penetration has only been shown to occur in the intraoperative or immediate postoperative period. We postulate that the perforation in this case is due to progressive th...

متن کامل

Actual Indications for Intracorneal Ring Segment Implantation in Keratoconus

Intracorneal ring segments (ICRS) are small synthetic implements designed to achieve refractive adjustment by flattening the cornea. Three common types of commercially available ICRS are Intacs, Keraring and Ferrara rings. Low myopia was the initial indication for implantation of ICRS, and indications later included ectatic corneal diseases (such as keratoconus and pellucid marginal degeneratio...

متن کامل

Reasons for intrastromal corneal ring segment explantation.

Reasons for intrastromal corneal ring segment explantation In their recent article, Ferrer et al. report that 57 of 250 implanted intrastromal corneal ring segments (ICRS) had to be explantedda rate of 22.8%. The main cause of this very high explantation rate was extrusion (48.3%). There are 2 major causes of ICRS extrusion: (1) superficial implantation of a segment and (2) a segment that is pl...

متن کامل

Surgical technique: coupling of intrastromal corneal ring segments for ectatic corneal disorders in eye bank corneas

The management of corneal ectasia is evolving, with intrastromal corneal ring segments playing an important role in delaying or eliminating the need for penetrating keratoplasty. This paper describes a modification in the implantation technique of intrastromal corneal ring segments that allows for coupling of the two segments with suture, affording more structural support.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of cataract and refractive surgery

دوره 36 1  شماره 

صفحات  -

تاریخ انتشار 2010