Tandem ion mobility-mass spectrometry (IMS-MS) study of ion evaporation from ionic liquid-acetonitrile nanodrops.

نویسندگان

  • Christopher J Hogan
  • Juan Fernández de la Mora
چکیده

Ion evaporation is an essential step in the formation of charged ions from electrosprays, yet many aspects of the process are poorly understood. The ion evaporation kinetics of the 1-ethyl-3-methyl-imidazolium+ (EMI+) based ionic liquids (ILs) EMI-BF4, EMI-bis(perfluoroethylsulfonyl)imide, EMI-bis(trifluoromethylsulfonyl)imide and EMI-tris(trifluoromethylsulfonyl)methide (EMI-Methide) are studied by tandem ion mobility-mass spectrometry (IMS-MS) of IL nanodrop residues from positive and negative electrosprays of IL-acetonitrile solutions. Two-dimensional (2D) IMS-MS spectra are obtained using a differential mobility analyzer (DMA) coupled to a commercial quadrupole-time-of-flight mass spectrometer. Nanodrops of different charge states (z=1,2,...,10,...) are separated into distinct bands in 2D DMA-MS spectra, allowing for determination of both nanodrop size (radius) and charge. With the exception of negatively charged EMI-BF4, all clusters observed are charged below the Rayleigh limit of both the ILs and acetonitrile, showing that the charge loss mechanism is ion evaporation. Solvation energies, DeltaG, of evaporating ions from acetonitrile are inferred from radius and charge state data. With the exclusion of EMI-BF4 in negative mode (DeltaG>1.84 eV), all are in the 1.54-1.65 eV range, considerably lower than previously reported for tetra-alkyl ammonium salts in formamide. Measured size distributions of EMI-Methide nanodrops agree with those predicted by ion evaporation theory, though with narrower widths observed for doubly and singly charged nanodrops.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simultaneous ion and neutral evaporation in aqueous nanodrops: experiment, theory, and molecular dynamics simulations.

We use a combination of tandem ion mobility spectrometry (IMS-IMS, with differential mobility analyzers), molecular dynamics (MD) simulations, and analytical models to examine both neutral solvent (H2O) and ion (solvated Na(+)) evaporation from aqueous sodium chloride nanodrops. For experiments, nanodrops were produced via electrospray ionization (ESI) of an aqueous sodium chloride solution. Tw...

متن کامل

Quantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)

The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...

متن کامل

Multi-stage Mass Spectrometry up to MS4 on a QTof System

K E Y W O R D S T-WaveTM ion mobility, IMS, MS, MS, structure elucidation A P P L I C AT IO N B E N E F I T S This application note illustrates how multi-stage mass spectra up to MS can be generated on a SYNAPT G2 HDMS System in a single experiment. This experiment avoids the need to trigger on, isolate, and fragment specific ions, as is done in directed MS methods. Moreover, the duty cycle rem...

متن کامل

Can ion mobility mass spectrometry and density functional theory help elucidate protonation sites in 'small' molecules?

RATIONALE Ion mobility spectrometry-mass spectrometry (IMS-MS) offers an opportunity to combine measurements and/or calculations of the collision cross-sections and subsequent mass spectra with computational modelling in order to derive the three-dimensional structure of ions. IMS-MS has previously been reported to separate two components for the compound norfloxacin, explained by protonation o...

متن کامل

Development and Validation of Bioanalytical Method for Simultaneous Estimation of Nebivolol Enantiomers in Human Plasma Using Liquid Chromatography-tandem Mass Spectrometry

The present study describes a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous determination of S-RRR and R-SSS nebivolol (nebivolol enantiomers) in human plasma using solid phase extraction technique. Method of both S-RRR and R-SSS nebivolol (nebivolol enantiomers) has been developed and validated using racemic nebivolol D4 as an internal standard. Analytes...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical chemistry chemical physics : PCCP

دوره 11 36  شماره 

صفحات  -

تاریخ انتشار 2009