Contralateral comparison of blue-filtering and non-blue-filtering intraocular lenses: glare disability, heterochromatic contrast, and photostress recovery

نویسندگان

  • Billy R Hammond
  • Lisa M Renzi
  • Sohel Sachak
  • Stephen F Brint
چکیده

PURPOSE To compare visual performance in eyes with intraocular lenses (IOLs) that filter short-wave blue light versus contralateral eyes with IOLs that do not filter visible blue light. METHODS In this prospective, assessor-masked study that was conducted at five clinics in the US, eligible candidates were at least 12 months postimplantation of a control IOL and a contralateral IOL that filtered blue light. Glare disability was defined as the intensity of a white-light annulus that obscured a subject's ability to see a central target. Heterochromatic contrast thresholds were defined as the intensity of a blue-light disk that obscured a central target. Photostress recovery time was the duration required to regain sight of the target after a five-second flash of annulus light. RESULTS Fifty-two subjects were evaluated. Mean glare disability was significantly less (P = 0.04) in the blue-filtering IOL group (1.97 ± 0.44 log μW/cm(2)) than in the control group (1.88 ± 0.43 log μW/cm(2)). Mean heterochromatic contrast threshold was significantly higher (P = 0.0003) in the blue-filtering IOL group (0.36 ± 0.43 log μW/cm(2)) than in the control IOL group (0.15 ± 0.49 log μW/cm(2)). Geometric mean photostress recovery time was significantly faster (P = 0.02) in the blue-filtering IOL group (21 ± 3 seconds) than in the control IOL group (26 ± 3 seconds). CONCLUSIONS Glare disability was significantly lower, heterochromatic contrast threshold was significantly better, and recovery from photostress was significantly faster in the eyes with blue-filtering IOLs than in the contralateral control eyes with IOLs that did not filter blue light.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Attenuating Photostress and Glare Disability in Pseudophakic Patients through the Addition of a Short-Wave Absorbing Filter

To evaluate the effects of filtering short wavelength light on visual performance under intense light conditions among pseudophakic patients previously implanted with a clear intraocular lens (IOL). This was a patient-masked, randomized crossover study conducted at 6 clinical sites in the United States between September 2013 and January 2014. One hundred fifty-four bilaterally pseudophakic pati...

متن کامل

Intraindividual comparison of color perception and contrast sensitivity with and without a blue light-filtering intraocular lens.

PURPOSE To investigate color perception and contrast sensitivity with and without additional glare in pseudophakic patients with a conventional intraocular lens (IOL) in one eye and a blue light-filtering IOL in the fellow eye. METHODS Twenty-three bilaterally pseudophakic patients with a conventional IOL (AcrySof SA60AT) and a blue light-filtering IOL (AcrySof Natural SN60AT) were tested for...

متن کامل

Comparison of Blue Light-Filtering IOLs and UV Light-Filtering IOLs for Cataract Surgery: A Meta-Analysis

BACKGROUND A number of published randomized controlled trials have been conducted to evaluate visual performance of blue light-filtering intraocular lenses (IOL) and UV light-filtering intraocular lenses (IOL) after cataract phacoemulsification surgery. However, results have not always been consistent. Therefore, we carried out a meta-analysis to compare the effectiveness of blue light-filterin...

متن کامل

Blue-Light Filtering Spectacle Lenses: Optical and Clinical Performances

PURPOSES To evaluate the optical performance of blue-light filtering spectacle lenses and investigate whether a reduction in blue light transmission affects visual performance and sleep quality. METHODS Experiment 1: The relative changes in phototoxicity, scotopic sensitivity, and melatonin suppression of five blue-light filtering plano spectacle lenses were calculated based on their spectral...

متن کامل

Comparison of contrast sensitivity and color discrimination after clear and yellow intraocular lens implantation.

PURPOSE To compare contrast sensitivity and color vision in patients in whom blue-light filtering and non-yellow-tinted intraocular lenses (IOLs) were implanted. SETTING Refractive Surgery Unit, Hospital NISA Valencia al Mar, Valencia, Spain. METHODS Forty eyes of 20 patients were enrolled in a blue-light filtering fellow-eye control study; patients were implanted with a yellow-tinted IOL (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2010