Biocompatibility pattern of a bicarbonate/lactate-buffered peritoneal dialysis fluid in APD: a prospective, randomized study.

نویسندگان

  • Andreas Fusshoeller
  • Marcus Plail
  • Bernd Grabensee
  • Joerg Plum
چکیده

BACKGROUND In chronic ambulatory peritoneal dialysis, bicarbonate-buffered fluids, with their neutral pH and less advanced glycosylation end-products (AGE) and glucose degradation products (GDP), have better biocompatibility than conventional peritoneal dialysis (PD) solutions. That difference may be more beneficial in automated peritoneal dialysis (APD), due to its more frequent exchanges and longer contact times with fresh dialysate. We performed a prospective, randomized study in APD patients to compare the biocompatibility of conventional and bicarbonate/lactate-buffered PD fluids. METHODS We randomized 14 APD patients to have APD with either conventional or bicarbonate/lactate-based fluids. After 6 months, both groups changed to the other solution. The overall observation period was 12 months. After 1 and 5 months and again after 7 and 11 months, phagocytotic and respiratory burst capacities of effluent peritoneal macrophages were determined. Plasma interleukin (IL)-6 and C-reactive protein (CRP) as well as effluent IL-6, CRP, transforming growth factor (TGF)-beta 1, AGE and CA125 concentrations were measured. Inflow pain was quantified using a patient questionnaire. RESULTS Respiratory burst capacity remained unchanged and phagocytotic activity increased significantly during APD (P<0.001) with the bicarbonate/lactate fluid. Effluent IL-6 release was significantly lower than with the lactate fluid (P<0.05). While in the effluent TGF-beta 1 was unaffected, AGE concentration was lower after bicarbonate/lactate treatment (P<0.05). Effluent CA125 concentration, an indicator of mesothelial cell integrity, was higher (P<0.05) in neutral effluents. Finally, patients' inflow pain diminished (P = 0.05) when using the neutral fluid. CONCLUSIONS The use of a neutral PD fluid in APD improved patients' inflow pain as well as biocompatibility parameters reflecting enhanced phagocytotic activity of peritoneal macrophages, reduced constitutive inflammatory stimulation (IL-6), reduced AGE accumulation in the peritoneal cavity and better preservation of the mesothelial cell integrity. From the biocompatibility point of view, a neutral fluid with low GDP content can be recommended as the primary choice for APD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved acidosis correction and recovery of mesothelial cell mass with neutral-pH bicarbonate dialysis solution among children undergoing automated peritoneal dialysis.

Acid-base balance and peritoneal membrane longevity are of utmost relevance for pediatric patients undergoing peritoneal dialysis (PD). PD fluids with neutral pH and reduced glucose degradation product contents are considered more biocompatible, because they preserve peritoneal cell functions in vitro. To investigate the clinical effects of a novel PD fluid buffered with 34 mM pure bicarbonate ...

متن کامل

Acid-base profile and predictors of metabolic acidosis in patients undergoing peritoneal dialysis with lactate- and bicarbonate-buffered peritoneal dialysis solutions.

Metabolic acidosis correction is one of the goals of renal replacement therapy. Correction of acidosis in peritoneal dialysis (PD) may be affected by PD modalities such as automated PD (APD) or by new solutions containing a combination of bicarbonate and lactate as a buffer [bicarbonate continuous ambulatory PD (CAPD)]. The aim of the present study was to examine the acid-base status of our PD ...

متن کامل

Automated peritoneal dialysis with 'on-line'-prepared bicarbonate-buffered dialysate: technique and first clinical experiences.

BACKGROUND Automated peritoneal dialysis (APD) has the possibility of increasing the dialysis efficacy by using higher fill volumes, frequent dialysate exchanges, and tidal techniques. It is then possible to treat patients adequately without residual renal function. The drawbacks of the required high amounts of dialysis solution of up to 30 litres per session are the high costs of lactate-based...

متن کامل

In vitro biocompatibility evaluation of a novel bicarbonate-buffered amino-acid solution for peritoneal dialysis.

BACKGROUND Conventional lactate-buffered peritoneal dialysis fluids containing glucose as the osmotic agent have been shown to compromise important peritoneal host defence functions. The current study employed an in vitro model using activated peripheral blood mononuclear leukocytes (PBMC) for the preclinical biocompatibility assessment of a novel bicarbonate-buffered peritoneal dialysis fluid ...

متن کامل

Biocompatibility and tolerability of a purely bicarbonate-buffered peritoneal dialysis solution.

BACKGROUND Novel peritoneal dialysis solutions are characterized by a minimal content of glucose degradation products and a neutral pH. Many studies have shown the biocompatibility of neutral lactate-buffered solutions; however, until now, the effect of purely bicarbonate-buffered solutions has not been intensively studied in vivo. METHODS This study was an open label, prospective, crossover ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association

دوره 19 8  شماره 

صفحات  -

تاریخ انتشار 2004