Purity Determination and DSC Tzero Technology
نویسنده
چکیده
The determination of absolute purity by DSC has been an accepted technique since the mid 1960s. One source of error in the purity method, that has limited its applicability and accuracy, is uncorrected thermal lag. New DSC instrumentation incorporates these corrections directly into the heat flow signal. This superior approach leads to improved peak resolution and to more accurate purity analysis. It is likely that this advance will allow purity analysis to be performed at faster heating rates and the purity method will be extended to higher levels of purity.
منابع مشابه
Determination of the melting temperature, heat of fusion, and purity analysis of different samples of zidovudine (AZT) using DSC
The determination of chemical purity, melting range, and variation of enthalpy in the process of characterizing medicines is one of the principal requirements evaluated in quality control of the pharmaceutical industry. In this study, the method of purity determination using DSC was outlined, as well as the application of this technique for the evaluation of commercial samples of zidovudine (AZ...
متن کاملMonitoring of Pentoxifylline Thermal Behavior by Novel Simultaneous Laboratory Small and Wide X-Ray Scattering (SWAXS) and Differential Scanning Calorimetry (DSC)
The thermal and structural evolutions associated to active pharmaceutical ingredient (API) purity are monitored using a laboratory instrument (S3-MicroCaliX) allowing simultaneous time-resolved X-ray scattering at both wide and small angles (SWAXS) as a function of temperature. This is performed simultaneously with differential scanning calorimetric (DSC) that is carried out in the same apparat...
متن کاملPreparation and purity determination of radiolabeled taxol and evaluation of its absorption in murine melanoma
Aim and Background:Taxol is a known substrate for P-glycoprotein, which induces drug resistance to cancerous cells. Therefore radiolabeled taxol can be a suitable probe for imaging of the P-glycoprotein transport ability to determine drug resistance. The aim of this study was to provide labeled taxol and to determine the rate of uptake in the tumor to evaluate the location of the tumor and the ...
متن کاملDevelopment of a new ferulic acid certified reference material for use in clinical chemistry and pharmaceutical analysis
This study compares the results of three certified methods, namely differential scanning calorimetry (DSC), the mass balance (MB) method and coulometric titrimetry (CT), in the purity assessment of ferulic acid certified reference material (CRM). Purity and expanded uncertainty as determined by the three methods were respectively 99.81%, 0.16%; 99.79%, 0.16%; and 99.81%, 0.26% with, in all case...
متن کاملThermoanalytical investigation of terazosin hydrochloride.
PURPOSE Thermal analysis (TGA, DTG and DTA) and differential scanning calorimetry (DSC) have been used to study the thermal behavior of terazosin hydrochloride (TER). METHODS Thermogravimetric analysis (TGA/DTG), differential thermal analysis (DTA) and differential scanning calorimetry (DSC) were used to determine the thermal behavior and purity of the used drug. Thermodynamic parameters such...
متن کامل