Manual external carotid artery manipulation for failed device advance through the stent in carotid artery stent placement. A technical note.

نویسندگان

  • Masaki Watanabe
  • Yutaka Kai
  • Teruyuki Hirano
  • Yuki Ohmori
  • Kiyoshi Kazekawa
  • Jun-Ichi Kuratsu
چکیده

We report herein the usefulness of a manual external carotid artery manipulation for failed advancement of devices through the stent in carotid artery stent (CAS) placement with open cell type stent and filter type distal protection device. In all, 22 consecutive patients underwent CAS with filter type protection device between April 2008 and December 2009 in our institution, and failed advancement of the devices through the stent occurred in 4 patients (18%). For all the 4 patients, the devices could be navigated normally through the stent under the manual external carotid artery manipulation. In cases with failed device advance in CAS, this maneuver would be one of the methods to resolve this.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Hemostatic closure device after carotid puncture for stent and coil placement in an intracranial aneurysm: technical note.

A 71-year-old female patient presented with a wide-necked carotid cavernous aneurysm for which stent and coil placement was planned. Arterial tortuosity required direct puncture of the common carotid artery for access. The procedure was performed while the patient was receiving antiplatelet and anticoagulative therapy. To avoid potentially hazardous and prolonged carotid compression, a closure ...

متن کامل

Carotid artery stent placement with distal balloon protection: technical considerations.

BACKGROUND AND PURPOSE Most neurologic events that complicate the carotid artery stent placement procedure are embolic. Strategies are being developed and evaluated for their ability to minimize the clinical embolic risk. The purpose of this study was to determine the feasibility, safety, and technical considerations of performing carotid artery stent placement with use of a distal balloon anti...

متن کامل

Adjuvant Tirofiban Injection Through Deployed Solitaire Stent As a Rescue Technique After failed Mechanical Thrombectomy in Acute Stroke

PURPOSE We present our experiences of intra-arterial tirofiban injection through a deployed Solitaire stent as a rescue therapy after failed mechanical thrombectomy in patients with acute ischemic stroke. MATERIALS AND METHODS Data on 18 patients treated with adjunctive tirofiban injection through a temporarily deployed Solitaire stent after failed mechanical thrombectomy were retrospectively...

متن کامل

A Case of Carotid Artery Stenting through Surgical Exposure and Direct Puncture of the Femoral Artery with Severe Arteriosclerosis Obliterans: A Technical Note

Objective: A case of carotid artery stent placement performed by exposing and directly puncturing the femoral artery through a small surgical incision is reported. Case Presentations: In this patient, who had undergone multiple bypass surgeries for arteriosclerosis obliterans of the bilateral lower extremities, the inguinal region was scarred and atrophied, and percutaneous puncturing of the fe...

متن کامل

Feasibility and safety of stenting for symptomatic carotid arterial dissection.

OBJECTIVE To determine the procedural feasibility and safety of carotid angioplasty and stent placement of carotid artery dissection (CAD) patients who had failed antithrombotic therapy in acute dissection. METHODS A series of 33 consecutive patients (mean age, 40.21 years; 29 men and 4 women) who underwent angioplasty and stent placement for symptomatic carotid artery dissection (sCAD) from ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of vascular and interventional neurology

دوره 6 2  شماره 

صفحات  -

تاریخ انتشار 2013