Amptek Application Note XRF-1: XRF Spectra and Spectra Analysis Software
نویسنده
چکیده
Setting up a system for first order results is straightforward. One can easily identify the major constituents in simple samples and obtain approximate concentrations. This is sufficient for some applications. However, second order effects are quite important for many applications. To obtain high accuracy, identify constituents with low concentrations, or operate on a wide variety of samples, second order effects must be addressed. To remove these second order effects and obtain high accuracy, properly configuring both the hardware and software is critical.
منابع مشابه
Elemental Composition Analyses in Thick Atmosphere Using the Atmospheric Electron-induced X-ray Spectrometer (aexs) Instrument,
Introduction: This paper describes the progress in the development and application of the AEXS instrument to determine elemental abundance by analysis of the excired XRF spectra. The AEXS is a miniature instrument based on the excitation of characteristic X-Ray Fluorescence (XRF) spectra from samples in ambient atmosphere using a focused electron beam. Operation in ambient atmospheres with mode...
متن کاملXRF-FP is a full-featured quantitative analysis package for XRF
AMPTEK INC. 14 DeAngelo Drive, Bedford, MA 01730-2204 U.S.A. APPLICATIONS • X-Ray Fluorescence • Thin-film Analysis • RoHS/WEEE Analysis • Teaching and Research • Art and Archaeology • Process Control • X-ray Tube Characterization FEATURES • Fundamental parameters (FP) • Analysis with or without standards • General bulk and thin-film analysis • Analyze up to 40 elements • Supports all Amptek de...
متن کاملApplication of Fourier Transform Infrared Spectroscopy (FTIR) for assessing biogenic silica sample purity in geochemical analyses and palaeoenvironmental research
The development of a rapid and non-destructive method to assess purity levels in samples of biogenic silica prior to geochemical/isotope analysis remains a key objective in improving both the quality and use of such data in environmental and palaeoclimatic research. Here a Fourier Transform Infrared Spectroscopy (FTIR) mass-balance method is demonstrated for calculating levels of contamination ...
متن کاملAn Artificial Neural Network Analysis of Low-resolution X-ray Fluorescence Spectra
An artificial neural network approach was used for the analysis of low-resolution XRF spectra. Instead of peak analysis and fitting the experimental results to a mathematical function as used by the conventional algorithms, the artificial neural network method takes the spectrum as a whole, comparing its shape with the patterns learned during the training period of the network. This method was ...
متن کاملRevisit of Forensic Analysis of Arsenic Poisoning Case 1998
High energy synchrotron radiation X-ray fluorescence (SR-XRF) spectra for the forensic analysis of Wakayama arsenic poisoning case, Japan, were revisited. The spectra were measured at SPring-8 synchrotron facility by Nakai in December 1998 and Mo, Sn, Sb, and Bi were used as index elements at that time to demonstrate that the suspected saleswoman’s pesticide and that found near the curry pot we...
متن کامل