Determination of an optimal organ set to implement deformations to support four‐dimensional dose calculations in radiation therapy planning

نویسندگان

  • Wafa Soofi
  • George Starkschall
  • Keith Britton
  • Sastry Vedam
چکیده

Surface-based deformable image registration to generate a four-dimensional (4D) dose calculation in radiation treatment planning requires the selection of a set of organ contours to represent a basis set to generate anatomic deformation. The purpose of the present work was to determine the optimal set of organs needed to generate a basis set for deformation in treatment planning for thoracic tumors such that the required computations are minimized but dose accuracy is high. Using retrospectively reviewed records, we calculated 4D dose distributions based on treatment plans for 10 patients with thoracic tumors using a deformable model algorithm in a research version of a commercial radiation treatment planning system. Various combinations of organs (total lungs, heart, spinal cord, external body surface) were used to generate the basis set for deformations used in the calculations. The external surface contour did not have a noticeable effect on the dose calculation. Total lung, heart, and spinal cord together provided an adequate set of deformation organs to generate accurate dose deformations. The magnitude of calculated dose differences had no obvious relationship to tumor parameters, including site, histologic type, disease stage, extent of motion, or degree of centralization.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of organ doses in radioiodine therapy using medical internal radiation dosimetry (MIRD) method

Background: Radioiodine therapy has proven to be an effective method in the treatment of patients with differentiated thyroid carcinoma after thyroidectomy. The scope of this study is to describe a method to obtain the dose of organs using medical internal radiation dosimetry (MIRD) method. At the end, the results of MIRD calculations were compared with thermoluminescent dosimeter (TLD...

متن کامل

Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties

Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...

متن کامل

استفاده از مدل برنامه‌ریزی خطی مختلط عدد صحیح جهت بهینه-سازی زاویه و شدت پرتو در پرتودرمانی با شدت مدوله شده

Introdution: Intensity- modulated radiation therapy is one of the treatment methods for cancer tumors. The effectiveness of this method is dependent on the accuracy and treatment planning quality. Therefore, there is a need for a plan to select the angle and intensity simultaneous optimum of radiation. Methods: In this study, an mixed integer linear programming model was proposed for simultane...

متن کامل

Pretreatment quality control of single isocenter half- beam treatment planning technique using an amorphous silicon electronic portal-imaging device (EPID)

Introduction: Electronic portal imaging devices (EPIDs) are fundamentally used for instantaneous verification of the patient set‐up, block shape, and leaf positions during radiation therapy. In radiotherapy, situations arise in which an inclined PTV must be treated mutually with adjacent nodal regions. This methodology is most widely used for matching tangential/lateral breas...

متن کامل

Calculations of Linac Photon Dose Distributions in Homogeneous Phantom Using Spline

Introduction Relative dose computation is a necessary step in radiation treatment planning. Therefore, finding an approach that is both fast and accurate seems to be necessary. The purpose of this work was to investigate the feasibility of natural cubic spline to reconstruct dose maps for linear accelerator radiation treatment fields in comparison with those of the simulation. Materials and Met...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2008