Visibility of epidermoid tumors on steady-state free precession images.

نویسندگان

  • Y Sakamoto
  • M Takahashi
  • Y Ushio
  • Y Korogi
چکیده

PURPOSE To determine whether steady-state free precession sequences improve the MR visibility of epidermoid tumors in comparison with spin-echo images. METHODS Patients were four women and three men with epidermoid tumors in the subarachnoid spaces. MR was performed with a 1.5-T superconductive unit. For steady-state free precession imaging, three-dimensional Fourier transform fast imaging with steady-state free precession (FISP) images were used (20-40/7 [repetition time/echo time], flip angle of 25 degrees). The visualization and contrast-to-noise ratio were compared in FISP images and spin-echo images. In one case, the images of FISP and fast low-angle shot were obtained with variable repetition times and flip angles to evaluate the best pulse sequences for the visualization of epidermoid tumors. RESULTS The contrast-to-noise ratios between tumors and cerebrospinal fluid ranged from 7.9 to 17.5 (average was 12.9) on FISP images. The average of contrast-to-noise ratios on T1, T2, and proton density-weighted spin-echo images were 1.6, 2.0, and 4.2, respectively. Three-dimensional Fourier transform FISP images best showed central nervous system and demonstrated epidermoid tumors excellently. CONCLUSIONS Epidermoid tumors in the subarachnoid spaces were better demonstrated on steady-state free precession (three-dimensional Fourier transform FISP) than on conventional spin-echo images.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison the Accuracy of Fetal Brain Extraction from T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (HASTE) MR Image with T2-True Fast Imaging with Steady State Free Precession (TRUFI) MR Image by Level Set Algorithm

Background Access to appropriate images of fetal brain can greatly assist to diagnose of probable abnormalities. The aim of this study was to compare the suitability of T2-True Fast Imaging with Steady State Free Precession (T2-TRUFI), and T2-Half-Fourier Acquisition Single-Shot Turbo Spin-Echo (T2- HASTE( magnetic resonance imaging (MRI) to extract the fetal brain using the level set algorithm...

متن کامل

Corticomedullary differentiation of the kidney: evaluation with noncontrast-enhanced steady-state free precession (SSFP) MRI with time-spatial labeling inversion pulse (time-SLIP).

PURPOSE To assess whether noncontrast-enhanced steady-state free precession (SSFP) magnetic resonance imaging (MRI) with time-spatial labeling inversion pulse (Time-SLIP) can improve the visibility of corticomedullary differentiation of the normal kidney. MATERIALS AND METHODS A series of noncontrast-enhanced SSFP MRI with Time-SLIP were performed in 20 patients by using various inversion tim...

متن کامل

MR of epidermoids with a variety of pulse sequences.

PURPOSE To assess the usefulness of fluid-attenuated inversion recovery (FLAIR) and constructive interference in steady state (CISS) sequences in depicting epidermoid tumors. METHODS Six patients with surgically confirmed epidermoid tumors in the subarachnoid space were examined with T1-weighted MR imaging with a spin-echo sequence, and with T2- and proton density-weighted imaging with a fast...

متن کامل

Real-time correction of rigid body motion-induced phase errors for diffusion-weighted steady-state free precession imaging.

PURPOSE Diffusion contrast in diffusion-weighted steady-state free precession magnetic resonance imaging (MRI) is generated through the constructive addition of signal from many coherence pathways. Motion-induced phase causes destructive interference which results in loss of signal magnitude and diffusion contrast. In this work, a three-dimensional (3D) navigator-based real-time correction of t...

متن کامل

MR temperature measurement in liver tissue at 0.23 T with a steady-state free precession sequence.

MRI can be used for monitoring temperature during a thermocoagulation treatment of tumors. The aim of this study was to demonstrate the suitability of a 3D steady-state free precession sequence (3D Fast Imaging with Steady-State Precession, 3D TrueFISP) for MR temperature measurement at 0.23 T, and to compare it to the spin-echo (SE) and spoiled 3D gradient-echo (3D GRE) sequences. The optimal ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 15 9  شماره 

صفحات  -

تاریخ انتشار 1994