Benefits of the Insertion Tip and Closed-System Sleeve for Intermittent Catheterization

نویسندگان

  • AM Holland
  • D Fish
چکیده

Purpose: Typically performed several times a day, intermittent catheterization (IC) is considered a generally safe and effective method for emptying the bladder and can be used on a short or long term basis as needed. Due to the potential risk of introducing bacteria into the urethra, recurrent urinary tract infections may occur even with appropriate hand washing and disinfection of the insertion site. In patients who routinely self-catheterize, catheter-associated urinary tract infections can be a serious problem. The purpose of this in vitro study was to assess the effectiveness of a closed system, which has a sleeved, pre-lubricated catheter with an insertion tip, in reducing bacterial transfer during the catheterization procedure. Materials and Methods: Nine catheters of each of two types were tested: Bard Touchless Plus Intermittent Catheter (14 Fr.) and Coloplast Self-Cath Intermittent Catheter (14 Fr.). The Bard Touchless Plus Intermittent Catheter incorporates an introducer tip and a closed system no-touch sleeve, while the Coloplast Self-Cath Intermittent Catheter consists of the catheter alone. Two tests were conducted to assess the effectiveness of these two design elements on the reduction of bacterial transfer during the catheter insertion procedure compared to the standard catheter. The first study (insertion tip test) measured the contamination of the catheter tip due to contamination from the user’s urethral meatus compared to the Bard Touchless Plus Intermittent Catheter with an insertion tip. The second study (closed system sleeve test) measured the contamination of the bare catheter shaft due to transfer from the user’s hands compared to the Bard Touchless Plus Intermittent Catheter with a no-touch sleeve. After completing simulated catheter insertion, sections of catheters were tested to determine the colony count of P. aeruginosa on the catheter after exposure to the contamination. Results: After the Insertion Tip test, the average colony count was 1.8 CFU/mL and 22.0 CFU/mL for the Bard Touchless Plus Intermittent Catheter and the Coloplast Self-Cath Intermittent Catheter, respectively. After the Closed System Sleeve test, the average colony count was 0.0 CFU/mL and 143.3 CFU/mL for the Bard Touchless Plus Intermittent Catheter and the Coloplast Self-Cath, respectively. Conclusions: In vitro studies suggest that incorporation of an insertion tip and a closed-system sleeve, as in the Bard Touchless Plus Intermittent Catheter system, reduces bacterial contamination of an intermittent catheter during the catheterization procedure. Further testing is required to determine if these in vitro findings have any impact on clinical outcomes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preventing Traumatic Urinary Catheter Insertion Through a Computerized Ordering System: Quasi-experimental Study From a Tertiary Academic Center

Background: Iatrogenic urethral injury is a well-known risk of urinary catheter insertion. Associated morbidities include stricture formation, catheter associated infection, risk for instrumentation, and extended length of stay. Yet, insufficient attention is paid to its prevention. Objective: This study aimed to assess the effectiveness of a computerized...

متن کامل

Psychometrics of the self-efficacy instrument of clean intermittent urinary catheterization in patients with neural bladder admitted to rehabilitation hospitals in Tehran in 2019

Background: The incidence of neural bladder is increasing today and these people need catheterization. Intermittent clean urinary catheterization is a low-risk method for the patients. Materials and methods: This was a descriptive methodological and validation research. For content validity, 10 people were selected by purposive method. For face validity, 25 people were chosen by convenience met...

متن کامل

A catheter malpositioned patient with pain and paresthesia

We report a 54-year-old woman with the history of end-stage renal disease (ESRD) who was admitted to our hospital because of volume overload. Due to long-term use of peripheral veins and arteriovenous fistula (AVF) failure, central venous catheterization was the only choice for hemodialysis. She developed right upper extremiti’s pain and paresis during hemodialysis. A posteroanterior chest x-ra...

متن کامل

Compliance With Guideline Statements for Urethral Catheterization in an Iranian Teaching Hospital

Background It is believed that healthcare staff play an important role in minimizing complications related to urethral catheterization. The purpose of this study was to determine whether or not healthcare staff complied with the standards for urethral catheterization.   Methods This study was conducted in Imam Reza teaching hospital, Tabriz, Iran, from July to September 2013. A total of 109 cat...

متن کامل

Health Benefits of Islamic Intermittent Fasting

Background & Objective:  Islamic fasting is observed by millions of Muslims across the world during the holy month of Ramadan and other specific  days of the lunar year. Fasting  Muslims  abstain from eating and drinking from dawn until sunset. Depending on season and geographical location, Muslims  maintain fasting for approximately 13-18 hours per day. The present study aimed to review the be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012