[Magnetic resonance imaging in the evaluation of congenital intracardiac shunts].
نویسندگان
چکیده
For many years, cardiac catheterization and angiocardiography have been the main diagnostic methods for morphological and functional assessment of congenital shunts. However, catheterization techniques are invasive, require injection of iodide contrast and exposure to x-rays, and complications may arise, particularly in pediatric patients. In the last 2 decades, echocardiography has progressively displaced invasive methods in the overall evaluation and definitive diagnosis of children and adults with congenital heart diseases.1 Although echocardiography is a safe, cheap technique that offers high diagnostic yield, it also has important limitations. The echocardiographic image is less clear in older children and adults than in infants and small children, in whom high-frequency transducers with high spacial resolution are required. In addition, multiple surgical interventions in older children and adults may cause further deterioration of the image. Although echocardiography provides high anatomic definition of almost any cardiac structure, it is virtually blind to what is happening outside the heart, a few centimeters into the vascular system. This technique is particularly limited in assessment of pulmonary or systemic venous drainage or peripheral pulmonary artery circulation. It is also very imprecise in evaluation of the thoracic aorta, congenital or surgical fistulas, or collateral systemic vessels. Echocardiography is even more limited in functional assessments. The size and function of the left chambers can be readily assessed by 2-dimensional echocardiography, but this technique is much less useful in the evaluation of the right chambers. Right ventricular function is particularly difficult to determine by echocardiography, but in congenital heart disease, the right ventricle may be of similar if not more importance Magnetic Resonance Imaging in the Evaluation of Congenital Intracardiac Shunts José M. Oliver-Ruiza and Monserrat Bret-Zuritab
منابع مشابه
Hysterosalpingography in the assessment of congenital cervical Anomalies: Pictorial Review
Cervical abnormalities may be congenital or acquired. Congenital anomalies of the cervix are rarely isolated, and more commonly accompany other uterine anomalies. Various imaging tools have been used in the assessment of Mullerian duct anomalies (MDAs). Currently, magnetic resonance imaging (MRI) is the modality of choice for definitive diagnosis and classification of the MDAs. Hysterosalpingog...
متن کاملCLINICAL CORRELATIONS BETWEEN AUDITORY BRAIN STEM RESPONSE AND MAGNETIC RESONANCE IMAGING IN PATIENTS WITH DEFINITE MULTIPLE SCLEROSIS
In an attempt to assess objectively the integrity of the auditory pathways in 30 patients with definite multiple sclerosis (MS), an audiometric evaluation was performed and auditory brainstem responses (ABRs) were obtained. Stressing the auditory system by increasing the stimulation rate showed some enhancement in the identification of MS. 24 (RO%) patients had an abnormal ABR along with c...
متن کاملLarge Sphenoethmoidal Encephalocele Associated with Agenesis of Corpus Callosum and Cleft Palate
Basal encephalocele is a rare craniofacial anomaly. In the present paper we report a 10-year-old boy presented with cleft palate, congenital nystagmus, and hypertelorism. During preoperative evaluation for cleft palate repair, a pulsatile mass was detected in the pharynx. Magnetic resonance imaging showed sphenoethmoidal type of basal encephalocele and agenesis of corpus callosum. Neurosurgical...
متن کاملنوزاد متولد شده با مالفورماسیون مادرزادی شریانی- وریدی مغزی و نارسایی احتقاقی قلبی: گزارش موردی
Background: Cerebral arteriovenous malformations are rare congenital anomalies presenting as different symptoms depending on their size and the age of patient. Congestive heart failure is a rare condition in neonatal period and is most common due to structural heart defects, but rarely may be a result of peripheral shunts such as cerebral arteriovenous malformation. Case presentation: A term...
متن کاملEffect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies
Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista espanola de cardiologia
دوره 60 9 شماره
صفحات -
تاریخ انتشار 2007