Radial single-shot STEAM MRI.

نویسندگان

  • Kai Tobias Block
  • Jens Frahm
چکیده

Rapid MR imaging using the stimulated echo acquisition mode (STEAM) technique yields single-shot images without any sensitivity to resonance offset effects. However, the absence of susceptibility-induced signal voids or geometric distortions is at the expense of a somewhat lower signal-to-noise ratio than EPI. As a consequence, the achievable spatial resolution is limited when using conventional Fourier encoding. To overcome the problem, this study combined single-shot STEAM MRI with radial encoding. This approach exploits the efficient undersampling properties of radial trajectories with use of a previously developed iterative image reconstruction method that compensates for the incomplete data by incorporating a priori knowledge. Experimental results for a phantom and human brain in vivo demonstrate that radial single-shot STEAM MRI may exceed the resolution obtainable by a comparable Cartesian acquisition by a factor of four.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Magnetic Resonance in Medicine 59:686–691 (2008) Radial Single-Shot STEAM MRI

Rapid MR imaging using the stimulated echo acquisition mode (STEAM) technique yields single-shot images without any sensitivity to resonance offset effects. However, the absence of susceptibility-induced signal voids or geometric distortions is at the expense of a somewhat lower signal-to-noise ratio than EPI. As a consequence, the achievable spatial resolution is limited when using conventiona...

متن کامل

Benefits of higher magnetic fields for diffusion tensor imaging (DTI) based on single-shot STEAM MRI sequences: In vivo mouse brain studies at 2.35 T and 7 T

Introduction In theory, the NMR signal is expected to scale more than linearly with magnetic field strength [1]. On the other hand, practical MRI applications such as diffusion tensor imaging (DTI) using echo-planar imaging (EPI) are also affected by a marked reduction of T2 and T2* relaxation times, the latter referring to enhanced magnetic field inhomogeneities with corresponding geometric di...

متن کامل

Single-Shot 3D Gradient and Stimulated Echo Imaging

Single-shot STEAM MRI [1] is insensitive to off-resonance effects because it is based on RF refocused echoes but suffers from a inherently low signal-to-noise ratio (SNR). Recently, gradient and stimulated echo (GRASTE) imaging [2] has been shown to ameliorate the limitations of single-shot STEAM by improving the SNR efficiency. Here, an extension of 2D GRASTE is presented that is capable of ac...

متن کامل

Half-Fourier single-shot STEAM MRI.

As a high-speed imaging technique based on stimulated echoes single-shot STEAM MRI is insensitive to chemical shift artifacts and magnetic susceptibility differences. The achievable signal-to-noise ratio (SNR) is limited by the fact that high flip angles of the read-out excitation pulses cause a steep decay of the stimulated echo train and therefore degrade the point-spread function of the resu...

متن کامل

High-field diffusion tensor imaging of mouse brain in vivo using single-shot STEAM MRI.

Information about the microstructural organization of cerebral white matter that is accessible by magnetic resonance diffusion tensor imaging (DTI) gains increasing importance for studies of animal brain. Particular challenges occur for in vivo conditions as well as at high magnetic fields. Here, we have employed a diffusion-weighted (DW) single-shot STEAM MRI sequence for DTI of mouse brain in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 59 4  شماره 

صفحات  -

تاریخ انتشار 2008