A comparison of the spinal board and the vacuum stretcher, spinal stability and interface pressure.
نویسندگان
چکیده
The interface pressures were measured between the sacrum, mid-lumbar spine and various support surfaces. Thirty healthy male volunteers were recruited. The spinal board, padded spinal board and vacuum stretcher were the support surfaces evaluated. We found high and potentially ischaemic pressures between the sacrum and the spinal board interface (mean 147.3 mmHg). This was reduced in the padded board (115.5 mmHg) but dramatically reduced with the vacuum stretcher (36.7 mmHg). It was also noted that no support was given to the normal lumbar lordosis by the spinal board (padded and unpadded), but support was given by the vacuum stretcher. This raises the question of how stable is an unstable spinal injury on a flat supporting surface.
منابع مشابه
Comparison of blood pressure measurements on the upper and lower extremities during spinal anesthesia
Introduction: During spinal anesthesia, measurement of blood pressure is often obtained by an indirect method using an inflatable cuff on the upper arm. The relationship between the blood pressure measurements at the two sites in patients undergoing spinal anesthesia is unclear. This study was designed to evaluate the difference observed in systolic blood pressure (SBP) taken from the upp...
متن کاملComparison of the therapeutic effects of promethazine and ephedrine stability of Hemodynamic patients undergoing arthroplasty with cement consumption
Introduction: In arthroplasty, spinal anesthesia was preferred to general anesthesia for a variety of reasons due to the use of cement. the side effects of cement on the cardiovascular system of patients, which can be catastrophic, it,s necessary to find appropriate treatment methods to reduce side effects of cement. method: In this clinical trial, 90 patients were arthroplasty candidates divid...
متن کاملThe Usability and Efficiency Human-Computer Interface in Cervical Spinal Cord injury by Game-based Electromyography Biofeedback and EMG Biofeedback
Background and Aims: The purpose of this study was to compare the efficacy and usability of human-computer interface in cervical spinal cord injury with two computer games based and EMG biofeedback. Methods: The sample size was 20 participants (healthy and spinal cervical lesions) who were selected as available. The statistical population of the study was spinal cord injury patients referred t...
متن کاملComparison of dexmedetomidine versus midazolam on hemodynamic parameters, bleeding, satisfaction of surgeons and patients who Underwent laminectomy surgery by spinal anesthesia
Background: One of the most empirical subjects particularly in substantial operations for example in surgeries involving the vertebral column, are the implication of sedatives in a manner which would create the least complications such as changes in the hemodynamic parameters. Two such drugs that are widely used in this capacity in clinical settings are midazolam and dexmedetomidine. Hemodynami...
متن کاملComparison of Intravenous bolus Phenylephrine and Ephedrine in the Prevention of Post- spinal Hypotension during Cesarean Section
Abstract Introduction: Spinal anesthesia is a commonly used anesthetic technique for cesarean section. The hypotension is the serious and common complication for it. Prevention of this complication is an important challenge for anesthesiologists. Objective: The aim of this study is to compare the effect of prophylactic bolus injection of Phenylephrine and Ephedrine in the prevention of hypote...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Injury
دوره 25 3 شماره
صفحات -
تاریخ انتشار 1994