Comparison of Cartesian and radial acquisition on short-tau inversion recovery (STIR) sequences in breast MRI

نویسندگان

  • Domiziana Santucci
  • Sheila S. Lee
  • Heidi Hartman
  • Shyama Walgampaya
  • Mamdoh AlObaidy
  • Miguel Ramalho
  • Brian M. Dale
  • Richard C. Semelka
چکیده

OBJECTIVE The purpose of this study was to compare two short-tau inversion recovery (STIR) sequences, Cartesian and radial (BLADE) acquisitions, for breast magnetic resonance imaging (MRI) examinations. MATERIALS AND METHODS Ninety-six women underwent 1.5 T breast MRI exam (48 Cartesian and 48 BLADE). Qualitative analysis including image artifacts, image quality, fat-suppression, chest-wall depiction, lesion detection, lymph node depiction and overall impression were evaluated by three blinded readers. Signal to noise ratios (SNRs) were calculated. Cronbach's alpha test was used to assess inter-observer agreement. Subanalyses of image quality, chest-wall depiction and overall impression in 15 patients with implants and image quality in 31 patients with clips were correlated using Pearson test. Wilcoxon rank sum test and t-test were performed. RESULTS Motion artifacts were present in 100% and in 0% of the Cartesian and the BLADE exams, respectively. Chemical-shift artifacts were present in 8% of the Cartesian exams. Flow artifacts were more frequent on BLADE. BLADE sequence was statistically superior to Cartesian for all qualitative features (p < 0.05) except for fat-suppression (p = 0.054). In the subanalysis, BLADE was superior for implants and clips (p < 0.05). SNR was statistically greater for BLADE (48.35 vs. 16.17). Cronbach ranged from 0.502 to 0.813. CONCLUSION BLADE appears to be superior to Cartesian acquisition of STIR imaging as measured by improved image quality, fewer artifacts, and improved chest wall and lymph node depiction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage

Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...

متن کامل

The STIR sequence in MR imaging.

A recent paper on MR imaging of infectious spondylitis [1) elaborated on and substantiated a previous report [2) of STIR in the evaluation of spinal infection. However, it also contained an important error in pulse sequence nomenclature: STIR was described as "short T1 inversion recovery. " The STIR sequence was described and named by Drs. Bydder, Young, and Steiner [3 , 4) as "short Tl inversi...

متن کامل

Magnetic resonance imaging of the sacroiliac joints in the early detection of spondyloarthritis: no added value of gadolinium compared with short tau inversion recovery sequence.

OBJECTIVES To investigate the additional value of T1 fat-saturated after gadolinium (T1/Gd) compared with T1 and short tau inversion recovery (STIR) sequence in detecting active lesions of the SI joints typical of axial SpA (axSpA) in a prospective cohort study, the SpondyloArthritis Caught Early (SPACE) cohort, and to assess its influence on final MRI diagnosis of the SI joint (MRI-SIJ) based ...

متن کامل

The Stir Sequence in MRI of Neoplastic Lesions

The Short Tau Inversion Recovery or STIR sequence was devised by Drs Bydder and Young of the Hammersmith Hospital to enhance lesions and suppress surrounding fat (1). Experience with seventy patients studied with suspected neoplastic conditions has shown that the use of the STIR sequence increases the sensitivity of MRI scanning. It also has the potential to decrease scanning and reporting time...

متن کامل

Chondral lesions in the patellofemoral joint in MRI: Intra-individual comparison of short-tau inversion recovery sequence (STIR) with 2D multiple-echo data image combination sequence (MEDIC)

PURPOSE To determine the value of the 2D multiple-echo data image combination (MEDIC) sequence relative to the short-tau inversion recovery (STIR) sequence regarding the depiction of chondral lesions in the patellofemoral joint. MATERIALS AND METHODS During a period of 6 month patients with acute pain at the anterior aspect of the knee, joint effusion and suspected chondral lesion defect in t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 50  شماره 

صفحات  -

تاریخ انتشار 2017