Establishing cytogenetic biodosimetry laboratory in Saudi Arabia and producing preliminary calibration curve of dicentric chromosomes as biomarker for medical dose estimation in response to radiation emergencies

نویسندگان

  • Khaled Al-Hadyan
  • Sara Elewisy
  • Belal Moftah
  • Mohamed Shoukri
  • Awad Alzahrany
  • Ghazi Alsbeih
چکیده

In cases of public or occupational radiation overexposure and eventual radiological accidents, it is important to provide dose assessment, medical triage, diagnoses and treatment to victims. Cytogenetic bio-dosimetry based on scoring of dicentric chromosomal aberrations assay (DCA) is the "gold standard" biotechnology technique for estimating medically relevant radiation doses. Under the auspices of the National Science, Technology and Innovation Plan in Saudi Arabia, we have set up a biodosimetry laboratory and produced a national standard dose-response calibration curve for DCA, pre-required to estimate the doses received. For this, the basic cytogenetic DCA technique needed to be established. Peripheral blood lymphocytes were collected from four healthy volunteers and irradiated with radiation doses between 0 and 5 Gy of 320 keV X-rays. Then, lymphocytes were PHA stimulated, Colcemid division arrested and stained cytogenetic slides were prepared. The Metafer4 system (MetaSystem) was used for automatic and manually assisted metaphase finding and scoring of dicentric chromosomes. Results were fit to the linear-quadratic dose-effect model according to the IAEA EPR-Biodosimetry-2011 report. The resulting manually assisted dose-response calibration curve (Y = 0.0017 + 0.026 × D + 0.081 × D2) was in the range of those described in other populations. Although the automated scoring over-and-under estimates DCA at low (<1 Gy) and high (>2 Gy) doses, respectively, it showed potential for use in triage mode to segregate between victims with potential risk to develop acute radiotoxicity syndromes. In conclusion, we have successfully established the first biodosimetry laboratory in the region and have produced a preliminary national dose-response calibration curve. The laboratory can now contribute to the national preparedness plan in response to eventual radiation emergencies in addition to providing information for decision makers and public health officials who assess the magnitude of public, medical, occupational and accidental radiation exposures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation Dose Estimation by Automated Cytogenetic Biodosimetry.

The dose from ionizing radiation exposure can be interpolated from a calibration curve fit to the frequency of dicentric chromosomes (DCs) at multiple doses. As DC counts are manually determined, there is an acute need for accurate, fully automated biodosimetry calibration curve generation and analysis of exposed samples. Software, the Automated Dicentric Chromosome Identifier (ADCI), is presen...

متن کامل

Cytogenetic biodosimetry: what it is and how we do it.

Dicentric assay is the international gold standard for cytogenetic biodosimetry after radiation exposure, despite being very labour-intensive, time-consuming, and highly expertise-dependent. It involves the identification of centromeres and structure of solid-stained chromosomes and the enumeration of dicentric chromosomes in a large number of first-division metaphases of cultured T lymphocytes...

متن کامل

Retrospective assessment of radiation dose by Fluorescence In Situ Hybridization and evaluation of stable chromosomal aberrations

Estimation of absorbed dose for radiation workers or person involved in different radiological accident is the aim of biodosimetry. Cytogenetic methods are the most current and applicable biodosimetry tools. In chronic or protracted exposure, fluorescence in situ hybridization (FISH), stable chromosomal aberration is used for estimation of absorbed dose. For precise estimation of absorbed dose,...

متن کامل

Biological Dose Assessment by Chemical Induction of Premature Chromosome Condensation

Dose assessment of radiation victims is a key element in medical management of radiation accidents. At high radiation doses (> 6 Gy), dicentric assay lose its efficiency and premature chromosome condensation (PCC) assay was proposed to overcome the restrictions of dicentric assay. It was shown that PCC ring is more suitable and simpler than dicentric for biodosimetry in high radiation doses. In...

متن کامل

Determination of dose-response relationship in cultured human lymphocytes for biological dosimetry

Background: Lymphocyte-dicentric assay is the most generally accepted method for biological dosimetry of overexposed individuals. In this study, the frequency of unstable chromosome aberration in blood lymphocytes was used to estimate radiation dose received by individuals. Evaluation of dose using a calibration curve produced elsewhere may have a significant uncertainty therefore, experiments ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2014