Continuous arterial spin labeling using a local magnetic field gradient coil.
نویسندگان
چکیده
Continuous arterial spin labeling (ASL) using a locally induced magnetic field gradient for adiabatic inversion of spins in the common carotid artery of human volunteers is demonstrated. The experimental setup consisted of a helmet resonator for imaging, a circular RF surface coil for labeling, and gradient loops to produce a magnetic field gradient. A spin-echo (SE) echo-planar imaging (EPI) sequence was used for imaging. The approach is independent of the gradients of the MR scanner. This technology may be used if the imaging gradient system does not produce an appropriate magnetic field gradient at the location of the carotid artery-for example, in a head-only scanner-and is a prerequisite for the development of a system that allows continuous labeling during the imaging experiment.
منابع مشابه
Continuous flow-driven inversion for arterial spin labeling using pulsed radio frequency and gradient fields.
Continuous labeling by flow-driven adiabatic inversion is advantageous for arterial spin labeling (ASL) perfusion studies, but details of the implementation, including inefficiency, magnetization transfer, and limited support for continuous-mode operation on clinical scanners, have restricted the benefits of this approach. Here a new approach to continuous labeling that employs rapidly repeated...
متن کاملSingle Coil Amplitude Modulated Continuous Arterial Spin Labeling Perfusion MR at 3.0 Tesla
J. Wang, Y. Zhang, R. L. Wolf, A. C. Roc, D. C. Alsop, J. A. Detre Department of Radiology, University of Pennsylvania, Philadelphia, PA, United States, Department of Neurology, University of Pennsylvania, Philadelphia, PA, United States, Department of Radiology, Harvard Medical School, Boston, MA, United States Introduction Recently technical developments demonstrated a greater than 2-fold SNR...
متن کاملCorrecting for off-resonance induced degradation of inversion efficiency in pseudo-continuous ASL
Introduction: Pseudo-continuous arterial spin labeling (pCASL) uses a long train of labeling pulses to provide multi-slice cerebral perfusion measurements while compensating for magnetization transfer effects without using additional hardware [1]. The inversion efficiency of pCASL is known to be sensitive to the amount of phase shift (φ) experienced during the time between two consecutive RF pu...
متن کاملFast, pseudo-continuous arterial spin labeling for functional imaging using a two-coil system.
A fast, two-coil, pseudo-continuous labeling scheme is presented. This new scheme permits the collection of a multislice subtraction pair in <3 s, depending on the subject's arterial transit times. The method consists of acquiring both control and tag images immediately after a labeling period that matches the arterial transit time. The theoretical basis of the technique, and simulations of the...
متن کاملTechnological advances in MRI measurement of brain perfusion.
Measurement of brain perfusion using arterial spin labeling (ASL) or dynamic susceptibility contrast (DSC) based MRI has many potential important clinical applications. However, the clinical application of perfusion MRI has been limited by a number of factors, including a relatively poor spatial resolution, limited volume coverage, and low signal-to-noise ratio (SNR). It is difficult to improve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Magnetic resonance in medicine
دوره 48 3 شماره
صفحات -
تاریخ انتشار 2002