A Novel Fault-Analysis Method for the Power Grid with Inverter-Interfaced Distribution Generators

نویسندگان

  • Zengli Yang
  • Lijun Wang
  • Hubing Zhou
  • Xianggen Yin
  • Fan Xiao
چکیده

Because of the special fault-current characteristics of the inverter-interfaced distribution generator (IIDG) , the conventional fault-analysis method based on the synchronous generator cannot be used for the power grid with IIDGs. The paper points out the problems of using the conventional fault-analysis method for the power grid with IIDGs and proposes a novel fault-analysis method for the power grid with IIDGs. Numerous simulation cases show that the proposed fault-analysis method is accuracte to meet the requirements of short-circuit calculation of the power grid and relay protection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transient Stability Enhancement in Microgrids Including Inverter Interfaced Distributed Generations

With increasing the presence of Microgrids (MGs) in the power systems, investigating the MG stability during transient faults is necessary. This study investigates the transient stability analysis of a MG supplied by multiple inverter interfaced distributed generations (IIDGs) during fault. The transient stability of a MG is highly depends on the IIDGs control strategy. A MG, simulated on Matla...

متن کامل

Novel Strategy for Accurate Locating of Voltage Sag Sources in Smart Distribution Networks with Inverter-Interfaced Distributed Generators

With the aid of power quality monitoring systems (PQMSs), accurate locating of voltage sag sources, which has important significance for guiding maintenance personnel in finding and repairing faults as well as improving power supply reliability, has been becoming a new research hotspot. However, existing methods have unsatisfactory locating accuracy due to the integration of distributed generat...

متن کامل

Low Voltage Ride-through (lvrt) of Grid Interfaced Wind Driven Pmsg

In renewable power generation the wind energy has been noted as the most rapidly growing technology; it attracts interest as one of the most cost-effective ways to generate electricity from renewable sources. Wind generation system has potential application for the grid support. The voltage of the direct driven permanent magnet wind generators (PMSG) is variable due to the intermittent nature o...

متن کامل

بهبود قابلیت گذر از خطای منابع تولید پراکنده مبتنی بر اینورتر با استفاده از محدود کننده‌ی جریان خطا

By increasing the penetration level of the inverter-based distributed generations (IBDGs) in power system, their fault ride through capability has become one of the essential issues of the new grid codes. This paper proposes a novel method to limit inverter fault currents which are used in DGs. To achieve FRT, interface-inverter operates as a controlled voltage source during normal operation as...

متن کامل

Control of Inverter-Interfaced Distributed Generation Units for Voltage and Current Harmonics Compensation in Grid-Connected Microgrids

In this paper, a new approach is proposed for voltage and current harmonics compensation in grid-connected microgrids (MGs). If sensitive loads are connected to the point of common coupling (PCC), compensation is carried out in order to reduce PCC voltage harmonics. In absence of sensitive loads at PCC, current harmonics compensation scenario is selected in order to avoid excessive injection of...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014