Errors in a stat laboratory: types and frequencies 10 years later.
نویسندگان
چکیده
BACKGROUND In view of increasing attention focused on patient safety and the need to reduce laboratory errors, it is important that clinical laboratories collect statistics on error occurrence rates over the whole testing cycle, including pre-, intra-, and postanalytical phases. METHODS The present study was conducted in 2006 according to the design we previously used in 1996 to monitor the error rates for laboratory testing in 4 different departments (internal medicine, nephrology, surgery, and intensive care). For 3 months, physicians and nurses were asked to pay careful attention to all test results. Any suspected laboratory error was recorded with associated pertinent clinical information. Every day, a laboratory physician visited the 4 departments and a critical appraisal was made of any suspect results. RESULTS Among a total of 51 746 analyses, clinicians notified us of 393 questionable findings, 160 of which were confirmed as laboratory errors. The overall frequency of errors, 3092 ppm, was significantly lower (P <0.05) than in 1996 (4700 ppm). Of the 160 confirmed errors, 61.9% were preanalytical errors, 15% were analytical, and 23.1% were postanalytical. CONCLUSIONS During the last decade the error rates in our stat laboratory have been reduced significantly. As demonstrated by the distribution pattern, the pre- and postanalytical steps still have the highest error prevalences, but changes have occurred in the types and frequencies of errors in these phases of testing.
منابع مشابه
Frequency of Errors in Clinical Laboratory Practice
Background and Objective: Laboratory errors are one of the major factors that affect the diagnosis, prognosis, treatment and monitoring in patients.The objective of study is to evaluate the frequency and type of errors in different phases of testing at the Pathology Department of the Shalamar Hospital, Lahore and to evaluate the causes of errors. Methods: This observational study was carrie...
متن کاملQuality indicators in the preanalytical phase of testing in a stat laboratory.
OBJECTIVE To quantify performance in the preanalytical phase in a stat laboratory using quality indicators, and compare our results with those in the literature to improve laboratory services. METHODS We counted the test request forms, samples, and the types of preanalytical errors that occured in a stat laboratory between January 1 and December 31, 2011. We then compared the quality-indicato...
متن کاملLean six sigma process improvement in specimen receiving to improve stat chemistry turnaround times
Objective: As a consequence of stat turnaround times (TATs) chronically exceeding 60 minutes, our laboratory was facing pressure to divert limited resources toward the implementation of an emergency department satellite laboratory. Peer-reviewed literature in clinical laboratory quality assurance and improvement indicates that between 60-70% of errors occur at the pre-analytical level. Thus...
متن کاملشیوع وقوع و نوع خطاهای دارویی و موانع گزارشدهی آن در پرستاران شاغل در یکی از بیمارستانهای آموزشی کرمانشاه
Background & Aim: The most common types of medical errors are medication errors. Medication errors can cause serious health problems and should be considered a threat to patients' safety. The aim of this study was to investigate the prevalence and types of medication errors and barriers to reporting errors by nurses in an educational hospital in Kermanshah University of Medical Sciences in 20...
متن کاملPreanalytical Errors in Hematology Laboratory- an Avoidable Incompetence
Background: Quality assurance in the hematology laboratory is a must to ensure laboratory users of reliable test results with high degree of precision and accuracy. Even after so many advances in hematology laboratory practice, pre-analytical errors remain a challenge for practicing pathologists. This study was undertaken with an objective to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical chemistry
دوره 53 7 شماره
صفحات -
تاریخ انتشار 2007